4
The green card edge POWER LED is not lit
check the PSU indicator to confirm that there is power to the frame
check the resettable fuses protecting the card - do this by removing the power
to the card for about 30 seconds then restoring the power
if necessary, refer to the power supply trouble shooting guide in the appropriate
ICON rackframe manual section
There is no output signal
ensure that the green power LED on the front of the card is lit
check that the inputs are connected to the rear panel and a valid signal is present
verify that the correct channel is selected - the LED on the button panel should
show the same channel number as the CHAN SEL LED on the front of the 4408
module
check the output connection from the rear panel to the monitoring device and
the output cable
ensure that the cable wiring and jumper link settings are correct for the
configuration used
The button panel will not select a different input
ensure that the jumper PL3 is correctly set to 'BUTTON' on all modules
check that the expansion cables are correctly installed
check that another, higher numbered, input is not permanently selected
The output signal is corrupted
check that jumpers PL4 and PL5 are set correctly for the configuration
ensure all expansion cables are installed correctly
In a 64x1 configuration, only half of the inputs are being routed
check that the 64x1 SEL line (PL6 ON) from pin 12 of CNTL on the rear panel from
each 32x1 block is properly connected to the SEL 1 and SEL 2 pins of the
combiner CNTL connector
check that an audio output is connected from each 32x1 block to the first two
combiner inputs
24