Switch
Position
1
OFF
1
ON
2
OFF
2
ON
Switch 3
Switch 4
OFF
OFF
OFF
ON
ON
OFF
ON
ON
All tones require a minimum of 180ms of ringing voltage (or contact closure) to trigger. Once triggered, the electronic
warble will run continuously until ringing stops (or contacts open). All other tones (double gong, quadruple chime,
doorbell) will run through their full sequence once and will not cycle again until the ringing stops (or contact opens) for
at least 50ms and a second ring signal (or contact closure) triggers them again.
A. Electronic Warble (Traditional Loud Ringer)
On
Off
B. Double Gong (Two "Gong" Tones)
575 Hz
C. Quadruple Chime (Four Descending Chime Tones)
On
888 Hz
Off
D. Door Chime (Ding-Dong)
On
Off

DIP Switch Programming

Description
Talk Battery disabled (use for paging port)
Talk Battery enabled (use for trunk input)
Normal Priority: Aux In → Page → Ringing
→ Background Music
Alternative Priority: Page → Aux In →
Ringing → Background Music
Sound Output Description
Electronic Warble (Loudest Sound)
Double Gong (Soft & Pleasant)
Quadruple Chime (Soft & Pleasant)
Door Chime (Soft & Pleasant)
Sound Output Specifications
2 seconds
0.74
2.2 sec
sec
575 Hz
0.36
0.36
sec
sec
699 Hz
0.36
sec
794 Hz
526 Hz
Frequency alternates between 1440 Hz and
1140 Hz 20 times per second.
0.36
2.2 sec
sec
584 Hz
492 Hz
2.7
sec
VIKING
MODEL PA-30
©
VIKING
ELECTRONICS
HUDSON, WI 54016
30 WATT TELECOM
PAGING AMPLIFIER
LOUD RINGING
70V OUT
1 2 3 4 5 6
7 8
9 10 11 12 13 14 15 16 17
LED2
LED4
LED3
C
C
C
on
1
2
3
4
LED
C
1
DIP Switches are
shown in factory
ON
default settings
OFF
MASTER
VOLUME
MIN
MAX
LED5
C
ON
1
2
3
4
5