DISASSEMBLY- AND RE-ASSEMBLY ADVISE
- No specific issues
REPAIR INSTRUCTION
- Hand unit tooth brush (1)
Never open the hand unit of the toothbrush because the
unit is no longer watertight after it has been opened.
Replace the entire unit in case of a defect.
When discarding the hand unit, remove the built-in
rechargeable battery.
The battery should be completely empty.
Instructions to remove the battery:
1. Pull of the housing.
2. Lift the battery out of the battery holder by means of a
screwdriver.
Note: After the housing has been removed, the appliance
may not be watertight anymore and the guarantee will
become invalid.
- Charging stand (2)
In case of a defective charging unit or damaged cord the
complete charging unit must be replaced.
OPTIONAL (accessories)
- No specific issues
PARTS LIST & EXPLODED VIEW
Pos
Service code
1
4203 035 51600
2
4203 035 53950
4203 035 53980
4203 035 53970
4203 035 53960