Schlage WPR400 User Manual
Schlage WPR400 User Manual

Schlage WPR400 User Manual

Wireless portable reader
Hide thumbs Also See for WPR400:

Advertisement

*P516-098*
P516-098
WPR400 Wireless Portable Reader
User guide
Para el idioma español, navegue hacia www.allegion.com/us
Pour la portion française, veuillez consulter le site www.allegion.com/us

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WPR400 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Schlage WPR400

  • Page 1 *P516-098* P516-098 WPR400 Wireless Portable Reader User guide Para el idioma español, navegue hacia www.allegion.com/us Pour la portion française, veuillez consulter le site www.allegion.com/us...
  • Page 2: Table Of Contents

    Link mode LED reference ....................9 Normal operation LED reference ..................9 Test mode ........................10 Set link mode on the PIM400 ..................11 Use the WPR400 in test mode ..................12 WPR400 test mode LED reference ................12 Improve RF communication ..................12 Batteries ..........................13 Troubleshooting ......................14...
  • Page 3: Overview

    When attached to a credential reader, normally operates in on-line (Reader) mode. • Information contained in the user credentials is passed to an access control panel (ACP), when in range of the ACP and the PIM400, which controls the WPR400 LEDs. The ACP maintains the audit trail. •...
  • Page 4: Wpr400 Operation

    WPR400 operation WPR400 range For optimum performance, the WPR400 should be operated within the following range limits: • Maximum distance between the PIM400 and WPR400 is 200 feet (61 meters) horizontally on the same floor in a building with normal construction materials.
  • Page 5: Permanently Or Temporarily Mount The Wpr400

    Mount the WPR400 using screws or Velcro strips. ® • The WPR400 should always be mounted at least one inch away from any metallic surface. • Place the WPR400 in a position where it was successfully link tested. Permanent mount with screws: 1.
  • Page 6: Schlage Utility Software (Sus)

    WPR400 reader with the Schlage button blinking alternate left–right red. 4. If unable to initiate coupling, follow the steps to reset the WPR400 to factory defaults. See Reset to factory defaults on page 9 for more information.
  • Page 7: Link To A Pim400 (Reader Mode Only)

    Link to a PIM400 (reader mode only) Each time it is turned on, the WPR400 will check the quality of its link to a PIM400, if a link had previously been made. If the previous link to a PIM400 cannot be re-established or it does not exist, the WPR400 will automatically attempt to link to a PIM400.
  • Page 8: Change The Rf Channel

    Changing the RF channel will terminate links with other WAPMs previously linked to the PIM400. The WPR400 radio frequency (RF) channel is controlled by the PIM400 it is linked with. The RF channel in use may be changed on the PIM400 through the Schlage Utility Software (SUS).
  • Page 9: Reset To Factory Defaults

    3 Red Link was unsuccessful 1 Z = RF channel number on which the WPR400 is linked (1-10). The RF channel of each PIM400 in the area should be known and recorded. 2 Number of beeps should match the RF channel number of the PIM400.
  • Page 10: Test Mode

    When powered on, the WPR400 will automatically enter test mode and test the quality of the RF link. If the RF link fails, the Schlage button will blink red three (3) times and five (5) short beeps will sound. Repeat the link attempt by either of the following methods (the PIM400 will remain...
  • Page 11: Set Link Mode On The Pim400

    6. The corresponding LED (LED1 for LINK1, LED2 for LINK2) blinks red and green. This indicates that the PIM400-TD2 is in Link Mode. To abort link mode, press the same switch again. J2, DC Power Link 2 Button Link 1 Button PIM400-TD2 printed circuit board (PCB) 11 • Schlage • WPR400 user guide...
  • Page 12: Use The Wpr400 In Test Mode

    2. Test on the intended door with the door open and with the door closed. 3. Turn on the WPR400. It will perform a power-on test and then automatically enter test mode. It will then send 200 test packets to check the quality of the RF link. A successful link will produce more green than red LED blinks during the link transmissions.
  • Page 13: Batteries

    3. Remove the battery retainer and battery holder. 4. Remove the old AA batteries from the battery holder. 8. Reattach the WPR400 cover making sure no wires are pinched. 13 • Schlage • WPR400 user guide...
  • Page 14: Troubleshooting

    Note: The intended use of this module is not for the general public. It is generally for industry/commercial use only. This transceiver is to be professionally installed in the end product by Allegion, and not by a third party. The Schlage XPB-COMAD400V2 900 MHz Communication Board Module will not be sold to third parties via retail, general public or mail order.
  • Page 15 To comply with IC RF exposure limits for general population/uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. 15 • Schlage • WPR400 user guide...
  • Page 16 Customer Service © Allegion 2015 P516-098 Rev. 12/15-e 1-877-671-7011 www.allegion.com/us...

Table of Contents