AIR FLOW TRANSDUCER
MODEL 6332/6332D
Operation Manual
Please read this manual carefully and understand the warnings
described in this manual before operating the product.
Keep this manual handy for ready reference
KANOMAX JAPAN, INC.
02001
0809
1

Advertisement

Table of Contents
loading

Summary of Contents for Kanomax 6332D

  • Page 1 AIR FLOW TRANSDUCER MODEL 6332/6332D Operation Manual Please read this manual carefully and understand the warnings described in this manual before operating the product. Keep this manual handy for ready reference KANOMAX JAPAN, INC. 02001 0809...
  • Page 2 Thank you for purchasing a product of Kanomax, Inc. Please read this operation manual carefully and operate the instrument appropriately by following the instructions given in this manual.
  • Page 3 Component List ■ Standard Item Model Remarks Airflow Transducer - 6332 Main Unit (Without Display) Airflow Transducer - 6332D Main Unit (With Display) ■ Probe & Cable (Sold Separately) Item Model Remarks 0962-00 Uni-directional 0963-00 0964-01 Omni-directional (Needle) 0964-02 0965-00...
  • Page 4 Important Safety Information In this operation manual, warning types and classifications are defined as follows. [Classifications] Danger: To Prevent Serious Injury or Death Warnings in this classification indicate danger that may result in serious injury or death if not observed. Caution: To Prevent Damage to the Product Warnings in this classification indicate risks of damage to the product that may void the product warranty if not observed.
  • Page 5 Danger ○ Never bring the probe close to a flammable gas atmosphere. --- The heated sensor may cause fire or explosion. Do not use near flammable gas ○ Never disassemble, modify or repair the instrument. --- Failure to observe the above may cause short circuit and malfunction.
  • Page 6 Caution ○ Do not use or leave the instrument in a high temperature/humidity environment, or in a dusty environment. The instrument must also not be left under direct sunlight for a prolonged period. Prohibited --- The instrument may not function properly outside Installation the specified temperature range of 5 to 40 degrees C.
  • Page 7: Table Of Contents

    Table of Contents Names and Dimensions of Components ..........1 System Configuration Example ............. 5 Connecting the Probe Cable to the Main Unit ........6 Connecting the Probe Cable to the Probe ..........6 Installing the Data ROM ................ 7 Switching Output (Setting Current/Voltage and Output Range) ...
  • Page 8: Names And Dimensions Of Components

    Names and Dimensions of Components Names and Dimensions of Components Names and Dimensions of Components Names and Dimensions of Components (1) Model 6332 View inside the Case Probe Cable Connector Output Range Changeover Changeover Switch ROM Socket Output Power Terminal Blocks...
  • Page 9 (2) Model 6332D View inside the Case Probe Cable Connector Display Substrate Output Range Changeover Changeover Switch ROM Socket Output Power Terminal Blocks...
  • Page 10 (3) Model 6332 View with the Case 4-φ4.5 Hole...
  • Page 11 (4) Model 6332D View with the Case 4-φ4.5 Hole...
  • Page 12: System Configuration Example

    System Configuration Example System Configuration Example System Configuration Example System Configuration Example Probe (Sold Separately) Probe Cable (Sold Separately) Display (Only 6332D) AC Adapter (Optional) Output Cable (Not Provided)
  • Page 13: Connecting The Probe Cable To The Main Unit

    Connecting the Probe Cable to the Main Unit Connecting the Probe Cable to the Main Unit Connecting the Probe Cable to the Main Unit Connecting the Probe Cable to the Main Unit <Caution> Make sure to cut the power supply to the main unit before connecting the probe cable (sold separately).
  • Page 14: Installing The Data Rom

    (Probe: Model 0963-00 shown for reference) A Installing the Data ROM Installing the Data ROM Installing the Data ROM Installing the Data ROM <Caution> Make sure to cut the power supply to the main unit before installing the Data ROM. Install the correct Data ROM that corresponds to the probe number.
  • Page 15: Switching Output (Setting Current/Voltage And Output Range)

    Switching Out Switch ing Output put ( ( ( ( Setting Setting Current/Voltage and Output Current/Voltage and Output Switch Switch ing Out ing Out Setting Setting Current/Voltage and Output Current/Voltage and Output Range) Range) Range) Range) <Caution> Make sure to cut the power supply to the main unit before switching the current/voltage output. Output can be set by either voltage output (0 to 5V) or current output (4 to 20mA).
  • Page 16 Output Changeover DIP Range Changeover Rotary Switch...
  • Page 17: Connecting Output And Power Supply

    Connecting Output and Power Supply Connecting Output and Power Supply Connecting Output and Power Supply Connecting Output and Power Supply <Caution> Pay attention to the polarity of power supply when connecting. Power supply voltage must be DC 12 to 24V. FG Terminal DC-IN Term.
  • Page 18: Measurement Method

    Measurement Method Measurement Method Measurement Method Measurement Method 1. Using the Uni-directional Probe (Model 0962-00, 0963-00) These probes have directivity characteristics which require the direction mark to be faced against the airflow for measurement. When you are not sure of the airflow direction, slowly rotate the probe in the horizontal direction, and select the point where the air velocity reading is maximum.
  • Page 19: Optional Accessory

    Optional Accessory Option al Accessory Option Option al Accessory al Accessory 1. Display Unit (Model 6332-01) Number of digits and range of air velocity value to be shown on the display corresponds to the setting of the air velocity output range as shown below. Output Range [m/s] Display Range [m/s] 0 ~ 2.00...
  • Page 20: Ac Adapter

    2. AC Adapter (Model 6332-02) <Caution> Do not connect the AC plug to the power receptacle before connecting the DC plug to the main unit. Failure to observe the above may cause short circuit and damage to the AC adapter. Observe the polarity and firmly insert the DC plug into the main unit as shown below.
  • Page 21: Cleaning The Probe

    Cleaning the Probe Cleaning the Probe Cleaning the Probe Cleaning the Probe If any impurities such as dust, soot and oil are attached to the sensor, the amount of heat that the airflow draws from the sensor surface (heat dissipation rate) will change, thus the air velocity reading will be affected.
  • Page 22: Specification Of Main Unit

    Specification of Main Unit of Main Unit Product Name Airflow Transducer (with / without Display) Model 6332 / 6332D Measuring Object Clean Airflow Maximum range 0.1 ~ 50 m/s (Depending on the measurement range of the Measuring Range probe*) Measuring Accuracy ±...
  • Page 23: Specification Of Probes (Sold Separately)

    Specification of Probes (Sold Specification of Probes (Sold Separately Separately) ) ) ) Specification of Probes (Sold Specification of Probes (Sold Separately Separately MODEL Measuring Range Sensor Type 0962-00 Uni-directional 0963-00 0.1~50.0m/s 0964-01 Omni-directional (Needle) 0964-02 0965-00 0.1~25.0m/s Omni-directional (Spherical) 0965-01 Mini-temperature-compensation-sensor 0965-03...
  • Page 24 Velocity Temp. Compensation Sensor Velocity Temp. Compensation Sensor Shielded Cable I-type L-type 00: protruding tip 01: no protrusion Velocity Temp. Compensation Sensor Shielded Cable I-type L-type...
  • Page 25: Troubleshooting

    Troubleshooting Troubleshooting Troubleshooting Troubleshooting Please check the following list before requesting a repair: Solution Symptom Possible Cause (& Reference Page) Supply power to the main unit. (Page No Output The main unit is not turned on. Wrong wiring of the output terminal. Provide proper wiring. (Page 10) Turn off the power.
  • Page 26: Product Warranty And After Service

    This storage period of replacement parts is considered as the period during which we can provide repair service. For further information, please contact our service center. When making an inquiry, please provide the following information. Please inform us: Product Name: Air Transducer Model Number: 6332 or 6332D Serial Number: xxxxxx Probe Model: Your Probe Model Description of Symptom in detail.
  • Page 27: Contact Information

    Contact Information Contact Information Contact Information Contact Information JAPAN KANOMAX JAPAN, INC. 2-1 Shimizu Suita City, Osaka 565-0805, Japan TEL: 81-6-6877-0183 FAX: 81-6-6879-5570 URL: http://www.kanomax.co.jp/ E-Mail: sales@kanomax.co.jp USA & EUROPE KANOMAX USA, INC. PO Box 372, 219 Route 206, Andover, NJ 07821 U.S.A.