Control Configuration - Fenwal 35-65 Series Manual

24 vac microprocessor based hsi control with 120/240 field selectable line voltage capability
Table of Contents

Advertisement

CONTrOL CONFIgurATION

35 - 6X X X X X
®
Page 8
Series 35-65, -66
HSI Control
- X X X
Description
Trial For Ignition
1 = 4 Seconds
3 = 7 Seconds
5 = 10 Seconds
7 = 15 Seconds
Inter-Purge
0 = None
1 = 15 Seconds
2 = 30 Seconds
Pre-Purge
0 = None
1 = 15 Seconds
2 = 30 Seconds
Tries For Ignition
0 = Single Try without Automatic Reset
1 = Single Try with 1 Hour Automatic Reset
5 = Three Tries without Automatic Reset
6 = Three Tries with 1 Hour Automatic Reset
35-65 Only (No blower relay) Termination For models
0 = ALL Q.C. Terminals Without Full Time Power (W Only)
1 = Mate-N-Loc (5 Pos.) with Q.C. Terminals without Full Time Power (W Only)
2 = Mate-N-Loc (2 Pos.) with Q.C. Terminals without Full Time Power (W Only)
5 = ALL Q.C. Terminals with Full Time Power (R Terminal)
6 = Mate-N-Loc (5 Pos.) with Q.C. Terminals with Full Time Power (R Terminal)
35-66 Only (With blower relay) Termination and Post Purge for models
0 = No Post-Purge All Q.C. Terminals without Full Time POWER (W Only)
1 = No Post-Purge All Q.C. Terminals with Full Time POWER (R Terminal)
2 = 30 Second Post-Purge All Q.C. Terminals *
3 = 60 Second Post-Purge All Q.C. Terminals *
5 = No Post-Purge Mate-N-Loc (5 Pos.) with Q.C. Terminals without Full Time Power (W Only)
6 = No Post-Purge Mate-N-Loc (5 Pos.) with Q.C. Terminals with Full Time Power (R Terminal)
7 = 30 Second Post-Purge Mate-N-Loc (5 Pos.) with Q.C. Terminals *
8 = 60 Second Post-Purge Mate-N-Loc (5 Pos.) with Q.C. Terminals *
Ignitor Options
0 = 120/240 VAC Mini-Ignitor (6 Second Heat-Up)
2 = 24 VAC Mini-Ignitor (4 Second Heat-Up) CE Approved
5 = 120/240 VAC Ignitor (20 Second Heat-Up)
6 = 120/240 VAC Ignitor (40 Second Heat-Up)
7 = 24 VAC Mini-Ignitor (4 Second Heat-Up)
Custom Designs - Standard Part Number Configuration Does Not Apply
3 = Customer Special Features CE Approved (Refer To Drawing)
8 = Aftermarket Kit (Refer To Drawing)
9 = Customer Special Features (Refer To Drawing)
Optional Features
1 = Dual Speed Blower (35-66 Model Only)
2 = 120/240 Field Selectable Line Voltage
3 = Dual Speed BLOWER AND 120/240 Field Selectable Line Voltage (35-66 Model Only)
5 = None
model
5 = Without Combustion Blower Relay (Model 35-65)
6 = With Combustion Blower Relay (Model 35-66)
400 MAIN STREET, ASHLAND, MA 01721
TEL: (508) 881-2000
FAX: (508) 881-6729
www.fenwalcontrols.com
© 2003 Kidde-Fenwal
Printed in U.S.A.
with 120/240 Field Selectable Line Voltage
These instructions do not purport to cover all the details or variations in the equipment
described, nor do they provide for every possible contingency to be met in connection with
installation, operation and maintenance. All specifications are subject to change without notice.
Should further information be desired or should particular problems arise which are not covered
sufficiently for the purchaser's purposes, the matter should be referred to KIDDE-FENWAL,
Inc., Ashland, Massachusetts.
TAG
www.fenwalcontrols.com
* Post-Purge Requires Full Time Power (R)
P/N 35.65, 66.02
6/20/03
1-800-FENWAL-1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

35-66 series

Table of Contents