Event Type
Fire Point Alarm
Fire Point Alarm Restore (Through Reset)
Waterflow Point Alarm
Waterflow Point Restore
General Alarm
Supervisory Point Active
Supervisory Point Restore
AC Trouble
AC Trouble Restore
Power Up/Reset
Fire Point Trouble
Fire Point Trouble Restore
Fire Trouble Restore (All Clear)
Fire Point Device Bypass (Disable)
Group, Zone or Panel Relay Bypass
(Disable)
Releasing Circuits Bypassed (Disable)
Releasing Circuits Unbypassed (Enable)
Fire Point Device Unbypass (ReEnable)
Group, Zone or Panel Relay Unbypass
(ReEnable)
NAC Bypass (Disable)
NAC Unbypass (ReEnable)
System Battery Trouble
System Battery Trouble Restore
NAC Circuit nn Trouble
NAC Circuit nn Trouble Restore
NAC Circuit Ground Fault
NAC Circuit Ground Fault Restore
FDLC Ground Fault Trouble
FDLC Ground Fault Trouble Restore
FDLC Trouble
Phone Line 1 Trouble
Phone Line 1 Trouble Restore
Phone Line 2 Trouble
Phone Line 2 Trouble Restore
Dialer Data Lost
Fire Test (Drill) begin
Fire Test (Drill) end
Quick Test Begin
Quick Test Stop
System Trouble qrs
System Trouble qrs Restore
Auto Test – System Normal
Manual Test – System Normal***
Point Active in Quick Test
***
Note: Below Panel Firmware revision 6.3, this code is always paired with the Auto Test Code (RP 30, etc.) during the daily automatic test.
nn denotes NAC circuit number 1-12.
d denotes FDLC number.
Important: Account 1 and Account 2 must be set for the same reporting format. See the FS-250 Programming
Manual, P/N 315-049403, or the FS-250C Programming Manual, P/N 315-049403C, as applicable, for details on
setting the reporting format.
P/N 315-699464-10
FS-DACT EVENT CODES
SIA DCS
Ademco
*
(8 or 20)
Contact ID
FA tuvw
1 110 xyz
FH tuvw
3 110 xyz
SA tuvw
1 113 xyz
SH tuvw
3 113 xyz
FA 298
1 110 298
SS tuvw
1 203 xyz
SR tuvw
3 203 xyz
AT 0
1 301 000
AR 0
3 301 000
RR 0
3 305 000
FT tuvw
1 373 xyz
FJ tuvw
3 373 xyz
FJ 9
3 373 009
FB tuvw
1 571 xyz
FB 298
1 571 298
SS 298
1 203 298
SR 298
3 203 298
FU tuvw
3 571 xyz
FU 298
3 571 298
FB 2nn
1 571 4nn
FU 2nn
3 571 4nn
YT 298
1 302 298
YR 298
3 302 298
FT 2nn
1 373 4nn
FJ 2nn
3 373 4nn
FT 299
1 373 299
FJ 299
3 373 299
FT 299
1 373 299
FJ 299
3 373 299
FT 30d
1 373 298
LT 1
1 351 001
LR 1
3 351 001
LT 2
1 352 002
LR 2
3 352 002
RT 30
1 354 030
FI 0
1 604 000
FK 0
3 604 000
FT 298
1 373 298
FJ 298
3 373 298
FT qrs
1 373 qrs
FJ qrs
3 373 qrs
RP 30
1 602 030
TX 30
1 601 030
FX tuvw
1 604 xyz
3
3/1
1400 Hz or
1400 Hz or
**
2300HZ
0
2
0
2
0
6
7
8
7
7
8
7
7
8
8
6
7
7
7
8
7
8
7
8
7
8
7
8
7
8
8
7
8
7
8
9
9
8
7
8
7
9
9
9
4/2
2300HZ
01
21
02
22
01
66
76
80
70
70
83
73
79
84
84
66
76
74
74
84
74
87
77
83
73
89
73
83
73
83
81
71
82
72
88
90
92
83
73
83
73
93
99
91