Cisco NCS 4200 Series Configuration Manuals page 8

Time division multiplexing configuration guide
Hide thumbs Also See for NCS 4200 Series:
Table of Contents

Advertisement

Device# show mpls l2 vc
Local intf
Local circuit
-------------
-------------------------- --------------- ---------- ----------
CE0/0/8
CEM 20
CE0/0/8
CEM 21
CE0/0/8
CEM 22
Verifying VCoP Smart SFP Configuration for STS-3C on OC-3
Use the show controller command to verify the VCoP smart SFP configuration.
Device#show controller sonet 0/0/10
SONET 0/0/10 is up.
Hardware is 12xGE-4x10GE-FIXED
Applique type is Channelized Sonet/SDH
Clock Source is Line
Medium info:
Type: Sonet, Line Coding: NRZ,
SECTION:
LOS = 0
LOF = 0
SONET/SDH Section Tables
INTERVAL
CV
15:58-16:11
0
LINE:
AIS = 0
RDI = 0
Active Defects: None
Detected Alarms: None
Asserted/Active Alarms: None
Alarm reporting enabled for: SLOS SLOF SF B1-TCA B2-TCA
BER thresholds:
SF = 10e-3
TCA thresholds:
B1 = 10e-6
Rx: S1S0 = 40
K1 = 00,
K2 = 00
J0 = 01
RX S1 = 00
Tx: S1S0 = 00
K1 = 00,
K2 = 00
J0 = 01
SONET/SDH Line Tables
INTERVAL
CV
15:58-16:11
0
High Order Path:
PATH 1:
AIS = 0
RDI = 0
LOP = 0
PSE = 0
LOM = 0
PLM = 0
Active Defects: None
Detected Alarms: None
Asserted/Active Alarms: None
Alarm reporting enabled for: PLOP LOM B3-TCA
TCA threshold:
B3 = 10e-6
Rx: C2 = 00
Tx: C2 = 00
PATH TRACE BUFFER : UNSTABLE
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
8
Dest address
2.2.2.2
2.2.2.2
2.2.2.2
ES
SES
SEFS
0
0
0
REI = 0
SD = 10e-6
B2 = 10e-6
ES
SES
UAS
0
0
0
REI = 0
NSE = 0
UNEQ = 0
VC ID
Status
3000
UP
3001
UP
3002
UP
BIP(B1) = 0
BIP(B2) = 0
BIP(B3) = 0
NEWPTR = 0
................
................
................

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents