Before connecting to the electrical system, make sure
the unit has been positioned properly and that the
electrical system is protected by fuses (as described in
Chapter 6.6).
As soon as you connect the unit to the battery and after
every reset the unit will start the automatic operation
mode.
The unit monitors the battery voltage and starts
charging as soon as the battery voltage drops bellow a
defined threshold. It will stop charging as soon as the
battery voltage exceeds the defined switch off
threshold.
The thresholds for automatic charging can be modified
with a computer – see Computer interface user
manual.
Please note that the device interrupts power
generation briefly several times an hour during
normal operation and a charging power of 0.0 A is
displayed then.
The second line of the display will indicate "charging
mode" as long as the unit is providing voltage to the
electrical system.
The device goes through a cold start phase of about 20
minutes before reaching its full rated output.
If the battery is sufficiently charged and the unit is not
providing input, the unit will remain in the standby
mode.
Should the device detect a malfunction such as an
empty fuel cartridge, it will shut down and advise you
how to correct the situation. ("Please change fuel
cartridge".) Resume automatic operation using the
reset button after the error has been corrected
(See Chapter 5).