Control Panel Trouble Shooting - Samsung RL23DATS Service Manual

Table of Contents

Advertisement

12. CONTROL PANEL TROUBLE SHOOTING

12-1 Sensor
1. Restart the appliance for a self-diagnosis before maintenance.
2. If self-diagnosis detects a fault, please refer to the following table for faulty parts.
NO
1
Refrigerating sensor
2
Deputy evaporator sensor
3
Freeze sensor
3.The sensors' positions are individually set forth hereunder:
Deputy evaporator sensor
4.The sensor resistance and the chip leg voltage under varying temperature.
Temp.
-35
68150
-34
64710
-33
61480
-32
58430
-31
55550
-30
52840
-29
50230
-28
47770
-27
45450
-26
43260
-25
41190
-24
39240
-23
37390
-22
35650
-21
33990
-20
32430
-19
30920
-18
29500
-17
28140
-16
26870
ITEM
DISPLAY
Refrigerating sensor
Freeze sensor
Voltage
Temp.
4.360
25650
-15
4.331
24510
-14
4.301
23420
-13
4.269
22390
-12
4.237
21410
-11
4.204
20408
-10
4.170
19580
-9
4.134
18730
-8
4.098
17920
-7
4.061
17160
-6
4.023
16430
-5
3.985
15740
-4
3.945
15080
-3
3.905
14450
-2
3.863
13860
-1
3.822
13290
0
3.778
12740
1
3.734
12220
2
3.689
11720
3
3.644
11250
4
REMARKS
Voltage
Temp.
3.597
10800
5
3.551
10370
6
3.504
9959
7
3.456
9569
8
3.408
9195
9
3.360
8839
10
3.310
8494
11
3.260
8166
12
3.209
7852
13
3.159
7552
14
3.108
7266
15
3.057
6992
16
3.006
6731
17
2.955
6481
18
2.904
6242
19
2.853
6013
20
2.801
5792
21
2.750
5580
22
2.698
5379
23
2.647
5185
24
24
Voltage
Temp.
2.596
5000
25
2.545
4821
26
2.495
4650
27
2.445
4487
28
2.395
4329
29
2.346
4179
30
2.296
4033
31
2.248
3894
32
2.199
3760
33
2.151
3631
34
2.104
3508
35
2.057
3390
36
2.012
3276
37
1.966
3167
38
1.922
3026
39
1.878
2962
40
1.834
2864
41
1.791
2770
42
1.749
3680
43
1.707
2593
44
Voltage
1.667
1.626
1.059
1.549
1.511
1.474
1.437
1.401
1.366
1.332
1.298
1.266
1.234
1.203
1.172
1.143
1.113
1.085
1.057
1.030

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rl23datwRl25datsRl28datwRl25datwRl28dats

Table of Contents