Refrigerating Cycle Block Diagrams - Samsung AS12A2VC Service Manual

Table of Contents

Advertisement

5. Refrigerating Cycle Block Diagram
INDOOR UNIT
T
1
Heat
exchanger
(Evaporator)
T
2
Refrigerating cycle temperature and pressure
Operating Condition
Standard
Cooling
Max over load
Low temp
Capillary tube
2-way valve
Liquid side
Gas side
3-way valve
STD Pressure
Piping Temp(°F)
(psi)
T1
3-Way Valve
64~78
50~54
-
61~64
-
34~39
OUTDOOR UNIT
Heat
exchanger
(Condenser)
Compressor
Use Temp. Condition(°F)
Indoor
T2
DB
WB
50~54
80
67
61~64
80
67
34~39
67
57
Cooling
Gas leak check point
Outdoor
DB
WB
95
75
115
75
67
57
19