Manaras Opera-H Installation Instructions Manual page 19

Opera series commercial garage door opener
Table of Contents

Advertisement

8.4.2
Reversing Edge Device (Non-Monitored)
• If the door is controlled by any device other than a constant pressure push-button station on close,
including a timer-to-close, a reversing edge must be connected.
Installation
Pneumatic Sensing Edge
1. Place the air switch in position, refer to Figure
30.
2. Place the air hose in position.
3. Use a coil cord or take-up reel to connect the air
switch to the operator terminals. Install electric
wires according to Figure 31 or Figure 32.
4. Connect one end of the air hose to the air
switch.
5. Place the air plug in the other end of the air
hose.
Electric Sensing Edge
1.
Place the junction box in position, refer to Figure 30.
2.
Place the sensing edge in position.
3.
Use a coil cord or take-up reel to connect the
sensing edge wires to the operator terminals.
Install electric wires according to Figure 33.
4.
Connect the sensing edge to the junction box.
5.
N/A
COM
3
SAFETY
6
Figure 31 - AIRSWITCH 001 / 007
For technical support, please call 1-800-361-2260 or visit
19
NOTICE
Adjustment screw
(Vis d'ajustement)
RED
YELLOW (NO)
Figure 33 - Electric Reversing Edge
5
Figure 30 - Reversing Edge
WHITE
SAFETY
GREEN (NO)
Figure 32 - AIRSWITCH 009
COM
3
SAFETY
6
2-Wire Edge
www.manaras.com
for more information
3
3
1
2
4
COM
3
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Opera-jOpera-shOpera-hjOphOpjOhj ... Show all