LT-5100 PC Real-time Video Controller V7.6
Page 6 of 22
Figure 5

5. Setting Controller Number:

Two ways to set: automatically distribution and manually setting:
1) Put the dip switch at "OFF", the controller will distribute a respective IP and a serial number for
each controller automatically;
2)Manual setting:
When multi-controllers work together, you need to set serial number to every controller(for
details , pls see《Table 5.1》).Through DIP switch the controller can change its serial number. The
DIP switch has 8 dials, from dial 1 to dial 8,each dial has 2 states,switch to "ON" denoting "0",
otherwise denoting "1". 8 dials of the DIP switch compose a 8 binary digit, NO 1 is the highest,
NO 8 is the lowest,the DIP switch is as shown in Figure 6;