Crescent SC500 Service Manual page 72

Hide thumbs Also See for SC500:
Table of Contents

Advertisement

Service Manual – SC500
Hidden Parameters
Code
Description
INOM
Nominal drive current
IMAX
Maximum drive current
TMAX
Protection trip time for IMAX
PDET
Detergent pump type
Factory
Min.
Max.
Value
Setting
Value
15A
10A
15A
45A
10A
45A
0 sec.
12 sec.
60 sec.
PST
PER
PER
05 - Control System, Magnetic Smart Key
Meaning
This is the maximum continuous current which can be
supplied to the electric wheel drive unit.
WARNING: increasing this value increases the risk
of the motor overheating.
This is the maximum instantaneous current which can
be supplied to the electric wheel drive unit.
WARNING: increasing this value increases the risk
of the motor overheating.
This is the reaction time of the electric wheel drive unit
protection device when overloaded: this parameter
is used in conjunction with IMAX to obtain the most
appropriate response curve for the overload protection
motor actuation system.
WARNING: increasing this value increases the risk
of the motor overheating.
Select "PST" for piston pump (factory installed on
Product Nr.: 9087352020, 9087354020, 9087350020,
9087351020, 9087353020, 9087355020)
Select "PER" for peristaltic pump (factory installed
on Product Nr.: 9087403020, 9087404020,
9087400020,9087401020, 9087405020, 9087402020)
72

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SC500 and is the answer not in the manual?

Table of Contents