, All rights reserved. No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from ShinewayTech as governed by international copyright laws.
GET-100 User’s Manual 3 Safety Instructions During each stage of operation of this instrument, please always observe the following safety instructions. Not taking any safety precautions or following the instructions will violate the safety standards of design, manufacturing and application of these instruments.
GET-100 User’s Manual Safety Terms Used in This Manual The WARNING sign denotes a hazard. It calls attention to a procedure, practice, or the like, which, if not correctly performed or adhered to, could result in personnel injury. Do not proceed beyond a WARNING sign until the indicated conditions are fully understood and met.
Page 5
GET-100 User’s Manual Any using of electric tools near inflammable gas or smog will be a big safety threat. In order to avoid electric shock, please don’t use instrument if there is damage on any outside surface part(top cover, panel, etc) ...
This Manual includes the essential information on correct operations and maintenance of GET-100 product, as well as guides to troubleshooting, technical services and support. Product introduction...
GET-100 User’s Manual Support MPLS testing and 3-level MPLS nest testing; Support service disruption time test (SDT); Support CoS and ToS/DSCP service priority testing; Statistical test data analysis; Support IP testing and testing of network connectivity;...
GET-100 User’s Manual 1.5 Keys on the front panel Key name Functional description Power button; see the shutdown interface by pressing it for a short time after starting up,and forced shutdown available by pressing it for a long time; Backlight key, adjusting backlight brightness;...
GET-100 User’s Manual Key name Functional description None Starting testing; stopping switchover Delete a character before cursor, and delete continuously by pressing for a long time; Delete the character(s) selected with cursor; Digital, letter and symbol input keys in 0—9, a-z, and 0-9, as well as such characters as *, +/- and #.displayed on the keys...
GET-100 User’s Manual transmissive laser. Don’t look in the eye the laser output port in device operation; Pull out the optical module and put on the dust cap after operation. 1.7 Descriptions of power source Following power sources may be applied for this device: ...
GET-100 User’s Manual 2 Basic operations for the device The basic operations will be described in this section, and the detailed usages should be described in the following chapters of this Manual. Please read this Manual carefully in order well to apply this product. If you have any question in use, please feel free contact technical support personnel of our company or agents.
GET-100 User’s Manual Switching over test mode 2.3 Opening/hiding port information bar Hide the port information bar by pressing the icon [ ] on the top right side in the tool bar referring to the system main interface; unfold the port information bar by pressing [ ] in the hiding state.
GET-100 User’s Manual 2.4 Starting application program Click corresponding testing port in system/testing port Tab on the top left side of the system main interface, then enter testing main interface of this port; enter the following interface by clicking ‘1G Fiber1’.
GET-100 User’s Manual 2.6 Test report Besides loopback, other testing application programs may generate test reports after testing. Click Storage button on the right of the tool bar, and store relevant settings and testing results as test reports for this testing, where, the reports are stored in an html format, and default names are the present time.
GET-100 User’s Manual 3 Common information setting of the system Enter the system interface after starting up; the system main interfaces mainly include the following seven buttons: [ ] System, [ ] Network, [ ] Calibrate screen, [ ] Power manager, [...
GET-100 User’s Manual System information setting On the right side is the contact information of the ShinewayTech Headquarters Service Center; On the top right side is the basic information of the instrument, including product serial number, platform and testing version numbers, software version, FPGA software version information.
GET-100 User’s Manual Time/date settings 3.1.3 Optional functions All testing modules available for the product are listed on the interface, and each item can be introduced briefly, where, the item marked with green √ in the front represents the function has been purchased, as shown in the following figure: Optional functions interface 3.2 Network settings...
GET-100 User’s Manual following figure: Network setting interface Note: Click ‘Connect’ button and enter effect after modification. 3.3 Screen calibration If abnormity occurs on the touch screen (e.g. current item is selected difficultly), the re-calibration should be required. Enter the screen calibration interface pressing on...
GET-100 User’s Manual Power manager interface Note: Cancel the screen stand-by state by pressing on any key or clicking any position on the screen in the stand-by screen. 3.5 Storage manager On the main interface after starting up, press down [...
GET-100 User’s Manual and pull out the USB. 3.6 System update On the main interface after starting up, press down [ ] and enter the system update interface; open the file folder where the update program exists, and select the update program; confirm Exit, and the system may restart update automatically by clicking Update button.
GET-100 User’s Manual 4 Testing parameters common parameter configuration 4.1 Test mode settings On the starting main interface, click ‘Test Mode’ on the top right side and select the test mode. 4.2 Port setting On the testing main interface, select the port setting [ ] to set such information as testing port network configuration.
GET-100 User’s Manual SFP/SFP parameters: SFP is the optical transceiver inserted in optical interface, the SFP module is selected for 10/100/1000M is optical interface. Laser power: the received laser power; Wavelength: 850nm, 1310nm and 1550nm; Speed: 1000M, 1G Fiber, etc.
Page 28
GET-100 User’s Manual interface, as shown as follows: Profile: Select the data stored previously in the preset values, and store the present setting information. IP: Select static IP or DHCP (dynamic host configuration protocol). When selecting DHCP, all parameters are values gained by DHCP automatically; when selecting static IP, manually input IP address information.
Bert: Error rate testing is mainly used to verify error codes in data transmission in transparent transmission of SDH/OTN/DWDM/dark optical fiber carried by Ethernet. GET-100 supports Layer 2-4 Bert testing in VLAN and MPLS environments. The engineer may set number of layers, size of frame, band width, MAC address and pseudorandom code pattern in the load area of Bert testing data frame by touch screen setting.
GET-100 User’s Manual Profile: Select preset configuration files; storing setting conditions is recommended often for follow-up test application. If deleting the configuration files, select in the pull-down items to delete it; if storing the configuration files, select, then confirm the setting name is saved and exit;...
Page 31
GET-100 User’s Manual Target MAC address: input manually, or click ARP button by inputting the correct target IP address, e.g. resolve the MAC address corresponding to target IP address; Source MAC address: input manually, or set default the MAC address of this device as source MAC address by pressing Default button;...
Page 32
GET-100 User’s Manual Type: VLAN type; and selectable VLAN types: 8100, 88A8 and 9100; Drop Eligible: Drop eligible: Give up marking Note: VLAN parameters can be configured after starting VLAN in the global setting; start three layers of VLAN at most.
Page 33
GET-100 User’s Manual Target IP address: Manually input IP address of the device to be tested, or by pressing From Control button, set the remote IP address set in the Control as the present IP address; Source IP address: Manually input IP address of the testing port, or by pressing From Interface button, set the IP address in interface setting as the present source IP address;...
Page 34
GET-100 User’s Manual package is abandoned by the router. TTL is set by the main transmission host, in case of endless circulation of data package in IP Internetwork. When IP data package is forwarded, the router is required to reduce TTL by 1 at least. Range is 0-255.
GET-100 User’s Manual Based on byte error code testing pattern, the selection scope for all layers of testing are as follows: When selecting Framed by framing in global setting, the Pattern may be selected as CRPAT (long continuous random testing code pattern) or CJPAT (long continuous jitter testing code pattern);...
Page 36
GET-100 User’s Manual Frame size: set the testing frame size to support the 9600 byte frame size at most; Const BW: set the testing bandwidth by % of line rate, or select G/M/K; Ramp: Ramp traffic testing: by configuring a series burst traffic, and start to send at the assigned min frame rate, up to the max frame rate gradually;...
Page 37
GET-100 User’s Manual testing bandwidths by % of line rate; or select G/M/K; Ramp time: set duration for each ramp step length by second (s), at 3-1000s; Burst: Burst traffic testing: configure two kinds of bandwidths; send by assigning the frame rate for each burst traffic;...
GET-100 User’s Manual Frame size: Set the testing frame size to support the 9600 byte frame size at most; Frame Num: Set the sent frame number; Band Width: Set the testing bandwidth by % of line rate, or select G/M/K;...
Page 39
GET-100 User’s Manual Source MAC address: filter out the frames in line with the setting in source MAC address from the received frames; VLAN ID: filter out the set frames in line with the setting in the outermost layer VLAN ID from the received frames;...
GET-100 User’s Manual 5.1.5 Remote control setting In the Bert testing interface, click the set Control and enter the remote control setting interface, which can be connected with the remote device; the interface is as follows: Target union: the far-end device may be locked by two ways: one is to input IP address of the far-end device directly, which is applicable for the determination of far-end IP address;...
GET-100 User’s Manual Tx stands for the sending end information, Rx is the receiving end information, and Accuracy is the precision of setting frame and data rates; the unit is determined in K/M/G, defaulted as Automatic. Line Rate: line rate of the test line;...
Page 42
GET-100 User’s Manual Bits: number of error codes received; BER: error code rate, i.e. ratio of the bytes of errors received in all received bytes, represented by the negative power of 10; FCS/CRC: invalid FCS/CRC frame number received; FCS/CRC(%): ratio of received invalid FCS/CRC frame number in total frame number;...
GET-100 User’s Manual Confirm and exit after setting; set the error inserting sending traffic of number by pressing on Error Insert button in the testing; the selectable error type for each layer of testing is as follows: First layer (Unframed): Bits...
GET-100 User’s Manual LOS: time losing optical port signal, by ms; it can display current interrupt time and accumulative interrupt time; Pattern LOS: the warning when error code exceeds limit value which is set in global setting interface; Business interruption: count the current or last business interrupt time, total business interrupt time, longest business interrupt time, shortest business interrupt time, and times of business interruption.
GET-100 User’s Manual <64: the frame at a length less than 64 bytes 64-127: the frame at a length of 64—127 bytes 128-255: the frame at a length of 128—255 bytes 256-511: the frame at a length of 256—511 bytes 512-1023: the frame at a length of 512—1023 bytes...
In GET-100 testing meter, RFC2544 test is packed as an automatic testing, and used to test items by freely selecting throughput, time delay, frame loss rate, and back-to-back, and to judge test results by the clear testing result table in UI.
GET-100 User’s Manual Configuration file: select the pre-storing configuration file; it is recommended the common setting conditions can be stored for the follow-up testing use. If deleting the configuration files, select [ ] in the pull-down menu for deletion; select [ ] to save the configuration files;...
Page 49
GET-100 User’s Manual Inclusive of 7 standard frame lengths and 2 user-defined frame lengths in IPv4 version, standard frame lengths for testing layers are as follows: Fram Frame Fram Frame Frame Frame Frame 1(byte) (byte) (byte) (byte) (byte) (byte) (byte)
GET-100 User’s Manual When the framing is UDP, the minimum frame length is 80 bytes in closing LVAN and MPLS. With one layer added for VLAN or MPLS, four bytes of the frame length increase. 6.1.3 Throughput setting On the RFC2544 testing interface, click the set Throughput and come into the throughput setting interface, as shown in the following figure: Max rate: set the max rate of throughput.
GET-100 User’s Manual Max rate: directly select the max rate value of cited throughput; or select customer rate for resetting, the unit is selectable, at a line rate of 0.01—100%; Testing time: set the testing duration at a range of 5—1000s;...
GET-100 User’s Manual Max rate: set the max rate to be tested. It is expressed by % of line rate, or by G, M and K, with a line rate at a range of 0.01—100%; Step length: set the testing stepping value. if the test at the max rate is not Passed, then the set max rate is reduced by step, till the test can be passed, at the max rate of 5—50%;...
Page 53
GET-100 User’s Manual control setting interface, as shown in the following figure: Targeted module: Lock the far-end device by two ways: one is to directly input the IP address of the far-end device, which is applicable for the determined far-end IP address;...
GET-100 User’s Manual layers set by the local framing consistent with the far-end loopback layer number. In testing, the local module sends the testing traffic to the far-end module to execute loopback, then the testing traffic comes back to the local module, and is received and analyzed by the local module.
GET-100 User’s Manual 6.2.3 Delay On the RFC2544 testing main interface, select Result-Delay, and come into the delay result interface, where, the delay of testing for frame lengths. The word is green for the qualified delay, while the word is red for the unqualified delay, as shown in the following figure: 6.2.4 Frame loss...
GET-100 User’s Manual Note: The test is done at the set max rate at the beginning of testing. When the frame loss exceeds the set threshold, the bandwidth reduces by step; continue the test till the test is qualified or the bandwidth reduces to the minimum value.
GET-100 User’s Manual 7 Traffic Generation 7.1 Configuring multi-traffic testing parameters Before configuring the testing parameter, set the port network information first. On the test main interface, select the port setting [ ]. Set testing mode, whether starting traffic control or not, and starting and closing of laser in the port tab; set the third layer of network information in the network tab.
GET-100 User’s Manual 7.1.2 Frame setting On the multi-traffic testing interface, select the set Frame and come into the frame setting interface for the frame information setting. The tab shown on the interface is related to configuration of the global setting.
GET-100 User’s Manual business, frame length and bandwidth can be set separately as follows: Frame size: set the testing frame length to support the 9600-byte frame length to the maximum. Const BW: set the testing bandwidth by % of line rate, or by G/M/K;...
GET-100 User’s Manual Results. The perquisite for this operation is to execute Discover [ ] first, and find out the targeted device to select the device. Confirm the IP address of this device is displayed in the target address bar, and exit.
GET-100 User’s Manual The Frame Loss statistics is added for the multi-traffic compared with Bert. The multi-traffic may be used to count the number of frame loss for traffics. Manually inserting error code Set the business traffic of inserting business, error type and number of errors inserted each time by pressing the Error Type button in the toolbar on the right of the interface.
GET-100 User’s Manual 7.2.4 Traffic statistics On the multi-traffic testing main interface, select Result-Traffic, and come into the traffic statistical interface, where, the statistical results by frame type and length are included. All contents see 5.2.4 Bert Testing Traffic Statistics as follows: Shineway Technologies, Inc.
GET-100 User’s Manual 7.2.5 Time delay statistics On the multi-traffic testing main interface, select Result-Delay, and come into the delay statistical interface, where, the loopback delay and jitter results can be browsed, defaulting to display overall results. If browsing the testing result of one traffic, select the traffic in the tab on the top right corner of the interface as follows: 7.2.6 Events...
GET-100 User’s Manual 8 Y.1564 ITU‐ T Y.1564 is a new testing standard introduced for the operators’ Ethernet service open and late troubleshooting. It is an official testing method for the Ethernet open. The method is mainly used to verify correct configuration and reliable performance in the mode of commercial and Ethernet business-carrying online business.
GET-100 User’s Manual Configuration file: select the pre-stored configuration file. It is recommended the common setting conditions can be saved for the follow-up testing. If deleting configuration file, select [ ] for deletion in pull-down menu; select [ ] to save the configuration file.
GET-100 User’s Manual 8.1.3 Business setting On Y.1564 testing interface, click Setting-Business, and come into the business setting interface as follows: Testing mode: four modes: loopback, up, down, up-down modes, which are set in Control. In up-down testing, the up and down parameters should be configured separately.
GET-100 User’s Manual be expressed by % of line rate, or by G, M and K; EIR: set excess information rate, i.e. the max business rate. It is expressed by % of line rate, or by G, M and K;...
GET-100 User’s Manual control setting interface. It may be connected with far-end device, and the interface is show as follows: Targeted device: Lock the far-end device by two ways: one is to directly input IP address of far-end device, which is applicable for determining far-end IP address;...
GET-100 User’s Manual It can display max throughput, frame loss rate, max jitter and delay the business traffic configuration testing, and the business traffic test passes the judgment or not. If yes, the judging result is shown as Pass; if not, it is shown as Fail.
GET-100 User’s Manual Service: display the steps set from min bandwidth to overshoot based on the set step value; Max throughput: max throughput of all steps; Frame loss rate: frame loss rate of all steps; Max jitter: max jitter of all steps;...
GET-100 User’s Manual 8.2.4 Events On Y.1564 testing main interface, select Result-Event, and come into the event record interface, where the recorded events in test are browsed in a chronological order, as shown in the following figure: Shineway Technologies, Inc.
9 Loopback 9.1 Global setting On testing main interface, click Loopback testing icon [ ] in the testing application, and come into the Loopback testing global setting interface, as shown in the following figure: Configuration file: select the pre-stored configuration file. It is recommended the common setting conditions can be saved for the follow-up testing.
9.2 Loopback filtering setting On the Loopback testing main interface, select the filtering tab, and come into the filtering interface, as shown in the following figure: Set the filtering condition and select the check box before the condition; loop back the received frame in line with the setting condition.
10. Ethernet testing tool 10.1 Ping Ping testing is used to detect the tested device is connected or not, and test the network rate based on time delay. Select Ping [ ] on the testing main interface, and enter Ping testing interface, as shown in the following figure: Settings: Destination address: fill in the destination IP address of the tested device;...
10.2 Discovery The Discover function is used to search for a ShinewayTech ® product at some IP section for the testing, so as to apply the Control Setting and search for far-end loopback device. On the testing main interface, select Discover [...
12. Warranty Information Terms of Warranty All ShinewayTech products are warranted against defective material and workmanship for a period of one (1) year from the date of shipment to the original customer.
reliable way. Contacting Customer Service Please check our web site (www.shinewaytech.com) for updates to this manual and additional application information. If you need technical or sales support, please contact local Shineway Technologies Customer Service. Shineway Technologies (China), Inc. : Address: Fl.7, Zhongtai Plaza, No.3 Shuangqing Rd, Haidian District,...
Need help?
Do you have a question about the GET-100 and is the answer not in the manual?
Questions and answers