1.
2.
3.
4.
5.
6.
7.
Remove the boiler cover.
Before removing the cover, disconnect the electrical
installations:
- main switch
- display
- safety thermostat
Unscrew the screws.
Unscrew the three screws from the figure, from the internal
side of the storage.
Remove the side cover.
Place hand under the sheeting and press lower corners
of theside cover.
Unscrew the screws.
Unscrew the two indicated on the figure, from the inside,
under the storage.
Removing the storage.
Lift the storage 20mm and then remove it to the side,
in the direction of the arrow.
Unscrew the screws.
Unscrew the three screws from the figure, from the funnel of
the storage.
Removing the funnel of the storage together with pellets
conveyor.
Lift the funnel of the storage together with the pellets
conveyorin the direction of the arrow (at an angle of 45°).
19