  • Page 2: Technical Specifications

    1.Technical specifications DESCRIPTION UNIT COMBO 25 COMBO 40 COMBO 60 Boiler power Water content in a boiler Required draft Supply electrical power: - Ignition stage - Operation stage Supply voltage Frequency Boiler weight Maximum operating pressure Maximum operating temperature °C...
  • Page 3 2. Display: Functions and use Figure 1 Short press Long press (3-5 seconds) Buttons Exit from the menu or sub-menu Activating Chrono function within the ON/OFF and resetting alarm Chrono menu Entering the system menu, Entering the main menu, saving setup, activating time setup setting up the keypad Visualization/Increasing values...
  • Page 4 3.Alarms DESCRIPTION STATUS NUMBER Safety thermostat HV1 Blocked Boiler door opened Blocked Turning off due to lack of fire Blocked Turning off due to excessive temperature in the boiler Blocked Turning off due to excessive temperature of exhaust Blocked Error in encoder: no signal Blocked Error in encoder: failed fan control Blocked...
  • Page 5: Operation Mode

    5.1 Combustion power settings Combustion power can be set via this menu. Setting mode may be manual or automatic. In the first case the user sets the power by himself, while in the other the system sets the combustion power in relation to the defined temperature. Pellet: 1-2-3-4-5-Auto Wood: 0-1-2-3-4-5-Auto 5.2 Thermostats...
  • Page 6 5.5.1 Modality It is used to activate and deactivate the program settings. Press button P3 Press button P3 and choose Daily, Weekly or Week End program using the buttons P4 or P6. Activation of Chrono program is done by pressing the button P3 (selected field flashes) and then the button P2 (Disabled changes to Enabled)
  • Page 7 5.5.2 Chrono Program Press the button P1 to return one step back and select the field Chrono Program. Press button P3 to enter the menu Choose Daily, Weekly or Week End program using the buttons P4 or P6 and press the button P3 to confirm Select the day of the week using the buttons P4 or P6 and press the button P3 to confirm.
  • Page 8 Within each day there are three programs that can be used. Press the button P3 (selected field flashes) and set the time of ignition of the boiler (ON) using the buttons P4 or P6. After setting the time press the button P3 to confirm. Press the button P6 to move to the field for boiler shutdown.
  • Page 9 Press the button P5 (symbol “√” appears) and setting of time for a specific day of a week is now activated. Press button P1 until the display shows the initial screen. The symbol indicating that the Chrono program is active now appears in top left corner of the screen. Programming for operation around midnight Set the clock to ON for the previous day at a specified time: for example, at 20:30 Set the clock to OFF for the previous day at 23:59...
  • Page 10: Keyboard Settings

    5.5.3 Manual charging with pellets / Load This option activates manual charging with pellets, while the motor-reducer works non-stop. Charging stops automatically after 600 seconds or by manual deactivation at any time by pressing OFF via the button P3. Activating this function is only possible when the boiler is switched off. Manual charging with pellets is only used during start-up of the boiler or when there are on pellets in the storage.
  • Page 11: Connection Diagram

    6.2 Keyboard Menu 6.2.1 Loading Menu (Learn Menu) This menu is used to load data from the motherboard. 6.2.2. Setting the contrast Display contrast setting menu. 6.3 System menu This menu is protected by a security password and can be used only by authorized service technician.
  • Page 12 FUNKCIJE CHARACTERISTICS 230Vac± 10% 50/60Hz Main line F1= fuse T5,0A Triac regulation max 1A Configurable output V2 – Pump Triac ON-Off max 1A Relay 3A max Heater Motor-reducer Triac ON-Off 1A max Contact ON-Off, Default valueclosed; Safety thermostat, input Hv1 Bypass of not used Contact ON-Off, Default valueclosed;...
  • Page 13: Connecting The Boiler To The Chimney

    7. Instructions for use Combined pellet and wood boiler ABC COMBO is designed for pellet combustion, and the addition of a grid into the combustion chamber of the boiler creates the possibility for the combustion of solid fuels. The boiler is designed using the most modern production technology and high-quality and certified materials, welded with...
  • Page 14: Boiler Installation

    7.1.2 Fuel ABC Combo Boiler is designed for burning wood pellets as well as solid fuel (wood and coal). Pellets used should meet the following standards: EN Plus, DIN Plus, Önorm-M-7135 or DIN 51731. It is recommended that the humidity of the wood does not exceed 25%.
  • Page 15: Connections Dimensions

    European standards. The boiler must not operate in flammable or explosive environments. 8.1.3 Connections dimensions ABC COMBO 25kW ABC COMBO 40kW - 60kW A – 1353mm – supply line A – 1504mm – supply line B – 150mm – return line B –...
  • Page 16 8.2 First commissioning of the boiler Check whether the burner is properly set § Check whether all spirals of the turbulator are in place § Connect the power supply cable to the 220V outlet § Turn the main switch to position 1 §...
  • Page 17 a protective cover supplied with the boiler should be mounted to the pipe § leading the pellet into the combustion chamber light a fire in the boiler and start the boiler by pressing the button P2 § it is necessary to close the upper and lower boiler door §...
  • Page 18 Figure 5 Press the connector in the middle and pull back Figure 6 Pull out the exhaust temperature probe from its port. Open the door of the opening for cleaning (from the back of the boiler Fig. 7) and clean the soot and ash deposits Unscrew Unscrew Figure 7...
  • Page 19 At the end of the heating season: Remove the fan housing and clean the dust with a vacuum cleaner taking care § not to damage the fan propellers Clean the flue pipes and check if the chimney is congested § Clean the storage for pellets from dust and tiny debris of pellets §...
  • Page 20 Remove the boiler cover. Before removing the cover, disconnect the electrical installations: - main switch - display - safety thermostat Unscrew the screws. Unscrew the three screws from the figure, from the internal side of the storage. Remove the side cover. Place hand under the sheeting and press lower corners of theside cover.
  • Page 21: Spare Parts Catalogue

    Spare parts catalogue:...
  • Page 22 R.Br. NAME OF THE POSITION POSITION NUMBER Boiler with connections S0670 Doors of the flue gasses chamber S0681 Burner housing S0510 Heater S0134 Burner housing gasket P02210 Burner P02087 Pellets conveyor S0615 Fireclay board P00195 Side left sheeting of the boiler S0620 Funnel of the storage S0618...