Phoenix SELO-B User Instructions

Electronic lock

Advertisement

Rotary handle for unblocking
Multifunction keys '1' and '2'
for entering figures and words,
and for menu navigation
Keys '0' - '9' for entering
numbers and plain text
• Battery condition 'full'
• Key marked 'Function' to
select the desired menu
from the setting mode
• Battery condition 1/3
• Key marked 'Function' to
return to next higher menu
level
• Keys '1' and '2' to
navigate through the menu
Electronic lock model SELO-B allows you to open the lock either immediately, after entering the valid 7- or 8-digit secret code, or after
expiration of a preset opening delay. The lock's time functions can be set such that access is only granted at the preselected times. The
maximum number of codes for clearing the lock is 40.

A) GENERAL

• The opening procedure consists of two operations: CLEARING
and UNBLOCKING.
• To start the opening procedure, check that the input unit is in
the vertical end position.
• All accepted key strokes will produce a response on the display.
• If the code number is keyed in by mistake, return to the starting
position of the lock by pressing the On/Enter key, and start
over.
• After entering the wrong secret code three times in a row, the
lock will automatically block all further entries for 5 minutes...
SELO-B (Version 1.0)
USER INSTRUCTIONS
the lock
Electronic lock
3 lines for entering codes and
displaying messages
1 line for displaying battery
condition and key functions
Function key for correcting data
input and selecting menu
functions
On/Enter-key to switch on the
unit, select functions and to set
the lock to its starting position
...If, after waiting for 5 minutes, the wrong code is entered
again, the lock will block itself for a further 20 minutes
(manipulation resistance). During this time, the remaining
delay is depicted on the display and not even the valid number
code will open the lock.
• If more than 30 seconds lapse between pressing any two
keys, the lock automatically switches itself off for safety
reasons. The opening procedure has to be started over.
• Once data have been stored (numerical codes, time frame and
user entries), not even a power failure will delete them.
• Battery condition 2/3
• Key marked 'Function' for
deleting the figure entered
last
• Battery condition 'almost
empty'

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SELO-B and is the answer not in the manual?

Questions and answers

Summary of Contents for Phoenix SELO-B

  • Page 1 Electronic lock model SELO-B allows you to open the lock either immediately, after entering the valid 7- or 8-digit secret code, or after expiration of a preset opening delay. The lock’s time functions can be set such that access is only granted at the preselected times. The maximum number of codes for clearing the lock is 40.
  • Page 2 SELO-B (Version 1.0) Electronic lock USER INSTRUCTIONS B) OPERATION Clearing the lock without opening Unblocking the lock - relocking and delay (factory setting) securing the lock 1) To unblock the lock during the five second readiness for opening, 1) Press On/Enter key. When the lock is ready for operation, the...
  • Page 3 SELO-B (Version 1.0) Electronic lock USER INSTRUCTIONS C) CHANGING THE NUMERICAL CODE TEST – TO BE PERFORMED WITHOUT FAIL!! For safety reasons, only reprogram the lock with the safe door open and blocked in the open position. Only after you are absolutely certain that the lock has been reprogrammed successfully and that the lock can be electrically cleared and mechanically unblocked using the new settings, should the door be closed.
  • Page 4 SELO-B (Version 1.0) Electronic lock USER INSTRUCTIONS D) CHANGING THE LANGUAGE Entering the setting mode to change the language setting Selecting a different language On/Enter ‘1’ ‘2’ 1) Press key. When the lock is ready for operation, the 1) Having entered the setting mode, use keys...

Table of Contents