Electrical Section - Dunkirk DXL-125 Installation, Operation And Maintenance Manual

Dxl series ii. cast iron gas fired boilers for forced hot water
Table of Contents

Advertisement

!
WARNING
Electrical shock hazard. Turn OFF electrical power
supply at service panel before making electrical
connections. Failure to do so could result in death
or serious injury.
Electrical Wiring
See wiring diagrams on the following two pages for
details.
Electrically bond boiler to ground in accordance with
requirements of authority having jurisdiction. Refer to
National Electrical Code, ANSI/NFPA 70.
Thermostat Installation
1.
Thermostat should be installed on an inside wall about
four feet above the floor.
2.
NEVER install a thermostat on an outside wall.
3.
Do not install a thermostat where it will be affected
by drafts, hot or cold pipes, sunlight, lighting fixtures,
televisions, a fireplace, or a chimney.
4.
Check thermostat operation by raising and lowering
thermostat setting as required to start and stop the
burners.
5.
Instructions for the final adjustment of the thermostat
are packaged with the thermostat (adjusting heating
anticipator, calibration, etc.)

ELECTRICAL SECTION

15
240009041
P/N
, Rev. C [04/30/2017]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxl-150Dxl-170Dxl-200

Table of Contents