Summary of Contents for Nidec-Shimpo FG-3000

  • Page 1 Presented By Dallas Ft Worth Austin Houston NicolScales.com 800.225.8181 Contact Us Nicol Scales & Measurement is an ISO Accredited Calibration Company that has provided calibration, repair and sales of all types of weighing and measurement products since 1931.
  • Page 2 At 110% of the rated capacity, the display will flash a warning. When mounting FG-3000 Series Digital Force Gauges, use M4 mount- ing screws with a maximum insertion depth of 7 mm into the gauge. Hand tighten mounting screws, DO NOT use tools. Do not use damaged clamp.
  • Page 3 3. SETUP 1.3 Menu Structure 3.1 Measurement The FG-3000 Series Force Gauge has multi-level menu interface The Measurement menu contains the Unit of measure and Mea- (Table 1-3) that enables simple navigation and programming. surement Mode sub-menus, as shown in Fig. 3-1.
  • Page 4: Saving The Measured Value

    3.3 Select Test Mode 4.1 Memory The FG-3000 has 3 types of Test Modes. Track: The real time measuring mode. Under this mode, press the ZERO key to tare any initial reading being displayed. Peak: In Peak mode, the maximum force will be recorded and displayed.
  • Page 5 5.2 Auto Power All data points can be cleared from memory under the Delete all The FG-3000 has an automatic power off function. With Auto Pow- sub-menu (Fig. 4-4). A confirm window will appear asking you to er on, if there is no operation performed within five minutes it will confirm.
  • Page 6: Communication Port

    5.6 Calibration Because of the sensor material performance or the influence of external factors, there may be errors of a certain level after a period of usage. It is recommended to send the force gauge to a specialized test- ing organization for calibration. Fig.
  • Page 7: Troubleshooting

    Do not disassemble the gauge by your- RS-232 Specifications: self or attempt to repair. If you cannot resolve the fault yourself, -Hardware Flow Control: None please contact Nidec-Shimpo. -Data word length: 8 bits -Stop bit: 1bit -Parity: None...
  • Page 8 11. CAPACITY AND RESOLUTION Model Capacity 10.00 1.000 35.00 2.200 FG-3003 Resolution 0.01 0.001 0.01 0.001 Capacity 50.00 5.000 180.0 11.00 FG-3005 Resolution 0.01 0.001 0.01 Capacity 100.0 10.00 350.0 22.00 FG-3006 Resolution 0.01 0.01 Capacity 500.0 50.00 1800 110.0 FG-3008 Resolution 0.01...