Singer Futura CE-200E Service Manual page 24

Table of Contents

Advertisement

Service Manual
16-2. Adjustment of "0" feed (continued)
Adjustment without removing front and rear covers
Note: Remove control panel assay before adjustment zero feed.
1. Pull out the control panel from the front cover.
2. Adjust by moving the motor gear in either direction with 1.5mm hex driver.
Repeat the process until desired feed balance is obtained.
Turn the screw (A) clockwise to adjust reverse stitch
Turn the screw (A) counter clockwise to adjust forward stitch
Original issue
Model
A
Feb. 2007
Page 24/55
CE-200E

Advertisement

Table of Contents
loading

Table of Contents