WARNING
Disconnect switch for over current protection given in the table below is to be installed
between the indoor unit and the outdoor unit.
Disconnect switch
15A
CAUTION
Be sure to refer the preceding diagram and do the correct fi eld wiring.
Wrong wiring causes malfunction of the unit.
Check local electrical codes and also any specifi c wiring instructions or limitation.

6. 3. Wiring method

(1) Service cover removal
• Remove the two mounting screws.
• Remove the service cover by pushing downwards.
Direction of the service
panel removal
(2) Conduit plate removal
• Remove the fi ve mounting screws.
• Remove the conduit plate.
Hook
(3 places)
Service cover
(3) Fasten the power supply cable and the connection cable to the conduit holder using
the lock nut.
(Open the knock out holes with the tool so as not to transform conduit plate if
necessary.)
Cable tie with clip [Large]
(Accessories)
Connection cable
Conduit plate
Connection cable
Power supply cable
(4) Connect the power supply cable and the connection cable to terminal.
(5) Fasten the power supply cable and connection cable with cable clamp.
45/36 type
45 type
36 type
UNIT A
UNIT B
UNIT C
UNIT A
UNIT D
UNIT D
UNIT E
Look nut
Knockout hole
UNIT B
UNIT C