Download Print this page

Sealey PWM2500SP Instructions Manual page 6

220bar 600ltr/hr self priming 6.5hp petrol

Advertisement

8.4.
AIR CLEANER.
8.4.1.
The air cleaner is situated below the fuel tank (see fig.2). To access the air cleaner elements, unclip the over-centre clips at the top and
bottom and remove the black cover to reveal the foam pads as shown in fig.11.
8.4.2.
Remove the foam pads from the air cleaner housing.
8.4.3.
Wash the foam pads with a household detergent or a high flash-point solvent and squeeze dry.
8.4.4.
Refit the two foam pads (coarse pad outermost) into the location and bed down.
8.4.5.
Replace air filter casing lid and secure with both over-centre clips.
‰ WARNING! Petrol is extremely flammable and potentially explosive. Do not perform maintenance on petrol associated components
where there is any source of ignition present such as cigarettes, sparks, naked flame or hot surfaces.
8.5.
MAINTENANCE
Before each use.
Check engine oil level.
Inspect the unit for evidence of oil and fuel leaks.
After the first month or 20 hours only.
Change the engine oil.
Every 50 hours.
Change the engine oil.
Every 6 months or 100 hours.
Change the engine oil.
Inspect and clean air filter.
Clean the deposit cup.
Clean spark plug and check gap.
Every 300 hours.
Replace air cleaner element.
Check valve clearances.
Check idling speed.
Clean spark plug and check gap.
Clean fuel tank fuel filter