Message
Displayed
E8
"Decrease
Inactive Time"
E9
"See
Troubleshooting
in Manual
U009
U025
U032
U086
U087
Probable
Cause / Event / Meaning
Too many Inactive Days and/or
Hours have been set for your lawn
area.
Mowing Frequency is too high for
current settings of Inactive Time.
Area setting is too high for current
settings of Inactive Time.
E 9 is displayed for all other error
messages that are not listed above.
Wait for the operational data to be sent via
the GSM module.
Switch off before lifting.
The mower is connected to
charging, but switched off.
Waiting for the perimeter signal.
The mowing motor has been
overloaded for too long.
Corrective
Action
Decrease the number of
Inactive Days and/or the
number of Inactive Hours.
Decrease Mowing
Frequency. See "Tell your
mower how often to mow".
Decrease area setting.
Press the Right arrow to
receive the stop reason
number and refer to our
online Help Center.
No action is required. As
soon as the operational data
has been sent, charging will
start. This may take a couple
of minutes.
It is required to switch Off the
System Switch before lifting
and carrying the mower.
Switch the System Switch to
'On' to allow charging.
Check all power cable
connections. The mower will
resume automatically.
No action required. The
mower will resume
automatically once cooled
down.
75
Need help?
Do you have a question about the RC312 Pro S and is the answer not in the manual?