Security Enable; Security Enable Read - NEC MultiSync C431 User Manual

External control
Hide thumbs Also See for MultiSync C431:
Table of Contents

Advertisement

22. Security Enable

22.1 Security Enable Read

This command is used in order to read the Security Enable.
1) The controller requests the monitor to read Security Enable
Header
SOH-'0'-Monitor ID-
'0'-'A'-'0'-'8'
Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h, 38h): Message length (8byte)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'C' (43h, 41h, 30h, 43h): Security password Command
'0'-'2' (30h, 32h): Enable Read
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 "Check code" for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies Security Enable to the controller.
Header
SOH-'0'-'0'-Monitor ID-
'B'-'0'-'A'
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', replying monitor's ID is '1'.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h,41h): Message length (10byte)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'C'-'0'-'2' (43h, 42h, 30h, 41h, 30h, 32h): Get Security Enable Disable Reply
EN: Status
00h: Disable
01h: Enable
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 "Check code" for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Message
STX-'C'-'A'-'0'-'C'-'0'-'2'-ETX
Message
STX-'C'-'B'-'0'-'C'-'0'-'2'-EN-ETX
(93/104)
Check code
Delimiter
BCC
CR
Check code
BCC
Delimiter
CR

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multisync c501Multisync c551

Table of Contents