BNI IOL-102-000-Z012
BNI IOL-104-000-Z012
BNI IOL-104-S01-Z012
BNI IOL-104-S01-Z012-C01
BNI IOL-104-S01-Z012-C02
BNI IOL-302-000-Z012
BNI IOL-302-S01-Z012
BNI IOL-302-000-Z042
User´s Guide

Advertisement

Table of Contents
loading

Summary of Contents for Balluff BNI IOL-102-000-Z012

  • Page 1 BNI IOL-102-000-Z012 BNI IOL-104-000-Z012 BNI IOL-104-S01-Z012 BNI IOL-104-S01-Z012-C01 BNI IOL-104-S01-Z012-C02 BNI IOL-302-000-Z012 BNI IOL-302-S01-Z012 BNI IOL-302-000-Z042 User´s Guide...
  • Page 2: Table Of Contents

    Actuator warning 46hex Identification 60hex 4.4. Errors 4.5. Events Technical Data 5.1. Dimensions 5.2. Mechanical Data 5.3. Electrical Data 5.4. Operating conditions 5.5. LED indicators Status LEDs LED I/O-Ports Appendix 6.1. Product ordering code 6.2. Order information Included material www.balluff.com...
  • Page 3: Notes For The User

    Notes for the user 1.1. About this guide This guide describes the Balluff Network Interface BNI IOL-…-Z0xx for the application as peripheral output module to establish connection of binary actuators. Hereby it is about an IO-Link device which communicates by means of IO-Link protocol with the superordinate IO-Link master assembly.
  • Page 4: Safety

    Safety 2.1. Intended use This guide describes the Balluff Network Interface BNI IOL-…… for the application as peripheral output module to establish connection of binary actuators. Hereby it is about an IO-Link device which communicates by means of IO-Link protocol with the superordinate IO-Link master assembly.
  • Page 5: Getting Started

    Balluff Network Interface / IO-Link BNI IOL-…… -Z0xx Getting Started 3.1. Connection overview Fig. 3-1: BNI IOL-…..-Z0xx 1 Mounting hole 9 Pin/Port LED: Signalstatus 2 Label 10 Standard I/O port 6 3 Status LED:Communication / module 11 Standard I/O port 4...
  • Page 6: Mechanical Connection

    The FE connection from the housing to the machine must be low-impedance And kept as short as possible. Module versions Sensor Hub Version Digital Port BNI IOL-102-000-Z012 8 Inputs BNI IOL-104-000-Z012 16 Inputs BNI IOL-104-S01-Z012 16 Inputs with single channel monitoring...
  • Page 7: Sensor Interface

    Balluff Network Interface / IO-Link BNI IOL-…… -Z0xx Getting Started 3.4. Sensor Interface Standard I/O port (M12, A-coded, female) Function Input Input Output In / Out pin4 pin4/pin2 +24V +24V +24V n.c. 0.1 A 0.1 A 0.1 A Output n. c.
  • Page 8: Io-Link Interface

    IO-Link Interface 4.1. IO-Link Data BNI IOL-102-000-Z012 Data transmission rate COM2 (38,4 kBaud) Minimal cycle time 3 ms Process data length 1 Byte input IO-Link Revision Process data cycle time 3 ms, minimal cycle time BNI IOL-104-000-Z012 Data transmission rate...
  • Page 9 Balluff Network Interface / IO-Link BNI IOL-…… -Z0xx IO-Link Interface BNI IOL-302-000-Z012 Data transmission rate COM2 (38,4 kBaud) Minimal cycle time 3 ms Process data length 2 Byte input, 2 Byte output IO-Link Revision Process data cycle time 12 ms, minimal cycle time BNI IOL-302-S01-Z012 Übertragungsrate...
  • Page 10: Prozess Data/ Input Data

    IO-Link Interface 4.2. Prozess data/ Input data BNI IOL-102-000-Z012 Byte BNI IOL-104-000-Z012 Byte www.balluff.com...
  • Page 11 Balluff Network Interface / IO-Link BNI IOL-…… -Z0xx IO-Link Interface BNI IOL-104-S01-Z012 Byte Byte www.balluff.com...
  • Page 12 IO-Link Interface BNI IOL-104-S01-Z012-C01 BNI IOL-104-S01-Z012-C02* Byte Byte Byte Identification byte 0 Identification byte 1 Byte Identification byte 2* Identification byte 3* BNI IOL-302-000-Z0xx Byte www.balluff.com...
  • Page 13 Balluff Network Interface / IO-Link BNI IOL-…… -Z0xx IO-Link Interface BNI IOL-302-S01-Z012 Byte Byte Short Circuit at Port x between Pin 1 and Pin 3 Short Circuit Port x = 1 Where x = 0…..7 Byte Byte Note: Actuator short circuit: overload or short circuit in the main against 0V Actuator warning: short circuit of the output signal against +24V www.balluff.com...
  • Page 14: Prozess Data / Output Data

    IO-Link Interface 4.3. Prozess data / Output data BNI IOL-302-xxx-Z0xx Byte No output data for: BNI IOL-104-xxx-Z012 BNI IOL-104-S01-Z012-C01 BNI IOL-104-S01-Z012-C02 www.balluff.com...
  • Page 15: Parameter Data / Request Data

    Balluff Network Interface / IO-Link BNI IOL-…… -Z0xx IO-Link Interface Parameter data SPDU Object Length Range Default value / Request data Index Index Sub- name index Vendor ID 2 Byte 0378 050702 050701 050704 050709 Device ID 3 Byte 050711...
  • Page 16 2 Byte 1-16 … FFFF Actuator warning*** 2 Byte 1-16 … FFFF Identification** 2 Byte 0000 … FFFFFFFF Identification*** 4 Byte 00000000 * Only in case BNI IOL-302-xxx-Z0xx ** Only in case BNI IOL-104-S01-Z012-C01 *** Only in case BNI IOL-104-S01-Z012-C02 www.balluff.com...
  • Page 17: Inversion Of The Inputs 40Hex

    Balluff Network Interface / IO-Link BNI IOL-…… -Z0xx IO-Link Interface Inversion of the BNI IOL-10x-xxx-Z012 inputs 40 BNI IOL-104-S01-Z012-C0x BNI IOL-302-xxx-Z0xx Byte Index Inversion Port (x): 0 - Normal 1 - Inverted Port Direction BNI IOL-302-xxx-Z0xx Byte Index Direction 0: Input 1: Output www.balluff.com...
  • Page 18: Fault State Of The Outputs Pin 4, 42Hex

    01 - 1 10 - Last state 11 - Not defined Fault State of the outputs BNI IOL-302-xxx-Z0xx Pin 2, 43 Byte Index Fault State Port (x) 00 - 0 01 - 1 10 - Last State 11 - Not defined www.balluff.com...
  • Page 19: Voltage Monitoring 44Hex

    Balluff Network Interface / IO-Link BNI IOL-…… -Z0xx IO-Link Interface Voltage BNI IOL-x0x-xxx-Z012 Monitoring BNI IOL-104-S01-Z012-C0x Byte Index *only for "302". Short circuit at Port x between Pin 1 and Pin 3 Short circuit port x = 1 Where x = 0…7...
  • Page 20: Identification 60Hex

    Parameter Value out of Range 4.5. Events IO-Link Revision 1.0 Event Code Description 0x5112 Low sensor voltage (US) 0x5114 Low actuator voltage 0x5160 Short circuit sensor supply 0x5410* Short circuit actuator supply / actuator warning *Only in case of BNI IOL-302-xxx-Z0xx www.balluff.com...
  • Page 21: Technical Data

    Balluff Network Interface / IO-Link BNI IOL-…… -Z0xx Technical Data 5.1. Dimensions 5.2. Mechanical Data Housing material Die-cast zinc housing IO-Link-Port M12, A-coded, male I/O-Ports M12, female, 5-poles Enclosure rating per IEC 60529 IP67 (only when plugged in and threaded in) Weight ca.
  • Page 22: Led Indicators

    LED I/O-Ports Indicator Function LED Pin 2 / Pin 4 Input signal / output signal = 0 Yellow static Input signal / output signal = 1 Input port : SC, short circuit Output port: Imax, over-current, short circuit, actuator warning www.balluff.com...
  • Page 23: Appendix

    Balluff Network Interface / IO-Link BNI IOL-…… -Z0xx Appendix 6.1. Product BNI IOL-x0x-xxx-Z0xx-C0x ordering code Balluff Network Interface IO-Link Interface Functions 102 = 8 dig. Inputs 104 = 16 dig. Inputs 302 = 16 dig. Inputs / Outputs Versions 000 = Standard version...
  • Page 24: Www.balluff.com

    Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.F. Germany Tel. +49 7158 173-0 Fax +49 7158 5010 www.balluff.com balluff@balluff.de...