Radio Configurations RBS 2207 Contents Introduction Mobile Telephone System Radio Base Station References Definitions Cabinet Types Frequency Bands Basic Configurations dTRU Topology CDU-J Configurations Site Cell Configurations (SCC) Single Band Configurations Dual Band Configuration Mixing CDU-G and CDU-J RX Cables...
RBS 2207 Radio Configurations Introduction The radio configurations described are valid for RBS 2207, equipped with a maximum of three dTRUs/six TRXs per cabinet. The descriptions include basic configurations and site cell configurations. Mobile Telephone System PSTN RBS 2000 Switching System...
Figure 2 An example of an RBS 2000 servicing a three-cell site Radio Base Station The Radio Base Station 2000 (RBS 2000) is Ericsson’s second generation of RBSs, developed to meet the GSM specifications for BTSs. References Digital cellular telecommunications system (Phase 2+);...
Page 5
Radio Base Station (RBS) An RBS constitutes all the equipment in an Ericsson base station, and may comprise several BTSs. Each RBS has one DXU, which consists of a maximum of six TRXs.
Radio Configurations RBS 2207 Site Cell Configuration (SCC) The SCC is a geographical concept describing how an area around one RBS site is divided into radio traffic areas. The following types of site are defined: Omni-site Radio coverage in one 360 degree sector, that is in one area, using one BTS.
RBS 2207 Radio Configurations The radio performance of a configuration is defined at the TX and RX antenna reference points at the RBS border. There is an X close to every reference point in the following figures. The RBS border is not included in the figures.
Page 8
Radio Configurations RBS 2207 TX1+TX2 TX1+TX2 TX1+TX2 Hybrid Hybrid Hybrid combiner combiner combiner dTRU with no hybrid dTRU with no hybrid dTRU with hybrid combiner in use combiner in use, combiner in use shared between 2 cells P011000B Figure 4...
RBS 2207 Radio Configurations CDU-J Configurations This section shows different configurations using CDU-J. The same configuration can exist using CDU-G but configured the same as CDU-J. Configuration 2x1 CDU-J without hybrid combiner CELL 1 LNA DPX dTRU (optional) CDU-J CELL 2...
Page 10
Radio Configurations RBS 2207 Characteristics for one cell GSM 1800 GSM 1900 Max. number of TRXs 1 (1 dTRU supports two sectors) Number of feeders Number of antennas Antenna configuration TX/RX + RX TMA configuration (optional) ddTMA + ddTMA Configuration 1x2 CDU-J with hybrid combiner...
Page 11
RBS 2207 Radio Configurations Characteristics Number of feeders Number of antennas Antenna configuration TX/RX + RX TMA configuration (optional) ddTMA + ddTMA Configuration 1x2 CDU-J without hybrid combiner LNA DPX dTRU (optional) CDU-J LNA DPX (optional) 1 = Antenna Reference Point without TMA...
The RBS with any number of dTRUs within the specified range inserted in the specified position order • CDU-G can exist in earlier versions of RBS 2207 Single Band Configurations This section describes single band configurations for CDU-J. CDU-J Single Band Configurations without Hybrid Combiner...
RBS 2207 Radio Configurations CDU-J Single Band Configurations with Hybrid Combiner Table 2 CDU-J configurations for GSM 800, P-GSM 900, E-GSM 900, GSM 1800 or GSM 1900 No. of Max no. of TRXs No. of antennas See: cells Cell: Cell: Figure 8 on page 11 (config.
RBS 2106 Antenna Configurations Introduction The various configurations available for the RBS 2106 are described according to the following example: 3 x 2 CDU-F Number Type of CDU of cells Number of TRX/cell P008245B CDU Configuration Key Figure 1 In the example above, the cabinet is configured for three cells, each using two Transceivers (TRX).
Page 18
Antenna Configurations RBS 2106 CDU-F CDU-G CD U- F CD U-G CD U- F CD U-G CD U- F CD U-G Fau lt Op en Fau lt RX 1 Op en Fau lt RX 1 Op en RX 2 RX 1 RX 2 RX 2 CD U bus...
Antenna Configurations RBS 2106 CDU-F Antenna Connections The antenna connectors are located in the antenna connection field, see Section 2 Antenna Connection Field on page 3. The antenna connectors are located on the top of the CDU, see the figures below.
RBS 2106 Antenna Configurations CDU-F Configurations Note: In the figures and tables that follow, only cabinets that are fully-equipped are shown. Configurations consisting of part of the fully-equipped cabinet can also be extracted from the following figures and tables. See Figure 2 on page 4, Figure 3 on page 5 and Figure 5 on page 6 for an illustration of each the column headers in the tables below.
Page 22
Antenna Configurations RBS 2106 Table 1 3x4 CDU-F Configuration Connector Feeder Conn. Cell Label Field Signal Connector CellA: DX1 TX/RX TX/RX A CellA: RXB RX B CellB: DX1 TX/RX TX/RX A CellB: RXB RX B CellC: DX1 TX/RX TX/RX A CellC: RXB RX B 8 (28)
RBS 2106 Antenna Configurations CDU-G Antenna Connections The antenna connectors are located in the antenna connection field, see Section 2 Antenna Connection Field on page 3. The antenna connectors are located on the top of the CDU, see the figures below.
Antenna Configurations RBS 2106 CDU-G Configurations Note: In the figures and tables that follow, only cabinets that are fully-equipped are shown. Configurations consisting of part of the fully-equipped cabinet can also be extracted from the following figures and tables. See Figure 2 on page 4, Figure 3 on page 5 and Figure 14 on page 15 for an illustration of each the column headers in the tables below.
Page 31
RBS 2106 Antenna Configurations Table 8 3x2 CDU-G and 3x4 CDU-G Configuration Connector Feeder Conn. Cell Label Field Signal Connector CellA: DX1 TX/RX1 TX/RX A CellA: DX2 TX/RX2 TX/RX B CellB: DX1 TX/RX1 TX/RX A CellB: DX2 TX/RX2 TX/RX B CellC: DX1 TX/RX1 TX/RX A...
Antenna Configurations RBS 2106 1x4 CDU-G without HCU and 1x8 CDU-G with HCU Configuration The figure below shows the 1x4 CDU-G without Hybrid Combiner Unit (HCU) and 1x8 CDU-G with HCU configuration. Cell Optional Optional P008233D Figure 18 1x4 CDU-G without HCU and 1x8 CDU-G with HCU Configuration Table 11 1x4 CDU-G without HCU and 1x8 CDU-G with HCU Configuration Connector...
RBS 2106 Antenna Configurations 1x6 CDU-G without HCU and 1x12 CDU-G with HCU Configuration The figure below shows the 1x6 CDU-G without HCU and 1x12 CDU-G with HCU configuration. Cell Optional Optional TX2 TX3 P008262B Figure 19 1x6 CDU-G without HCU and 1x12 CDU-G with HCU Configuration Table 12 1x6 CDU-G without HCU and 1x12 CDU-G with HCU Configuration Connector...