Page 2
TX7320 Addressable Sounder Installation & Operation Manual Product Safety To prevent severe injury and loss of life or property, read the instruction carefully before installing the Sounder to ensure proper and safe operation of the system. European Union directive 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union.
1 Introduction 1.1 Overview The TX7320 Addressable Sounder is alarm warning device used to notify persons in the vicinity of the occurrence fire emergency in order the person to take appropriate measures. The unit adopt multi- application device starting from the types, parameters and wiring layout in single unit. Parameters...
TX7320 Addressable Sounder Installation & Operation Manual 2 Installation 2.1 Installation Preparation This alarm warning device must be installed, commissioned and maintained by a qualified or factory trained service personnel. The installation must be installed in compliance with all local codes having a jurisdiction in your area or BS 5839 Part 1 and EN54.
TX7320 Addressable Sounder Installation & Operation Manual 3 Sounder Configuration 3.1 Preparation The TX7930 handheld programmer is used to configure sounder soft address and parameters. This tools are not included, must be purchased separately. The programmer is packed with twin 1.5V AA battery and cable, ready for usage once received.
TX7320 Addressable Sounder Installation & Operation Manual 3.3 Single and Dual Address Mode Single address is commonly used to program immediate Evacuate tone while the dual address used for programming Pre-alarm and Evacuate tones respectively in a given period of time.
Note: If display “Success”, means the entered type is confirmed. If display “Fail”, means failure to program the type. No use for TX7320 to select Strobe Mode. 4. Press “Exit” key to go back Main Menu. Press “Power” key to switch off the programmer.
Note: Select 5 and 6 for both ⑤Strobe ⑥Sound 4. Set visible and audible signal. [Default 5 and 6] No use for TX7320 to select Strobe Mode. Figure 12 Figure 13 3.6 Tones Selection The Tones can be change according to the project requirement...
TX7320 Addressable Sounder Installation & Operation Manual 1. Attach the programming cable to 1 and 6 Terminals of sounder. Press “Power” to switch-on the unit. 2. Switch-on the programmer, then press button “4” to enter to Setting mode (Figure 14). The programmer will display the actual configuration after few seconds.
TX7320 Addressable Sounder Installation & Operation Manual 4 General Maintenance 1. Inform the suitable personnel before conducting the maintenance. 2. Disable the alarm warning device on the control panel to prevent false alarm. 3. Do not attempt to repair the circuitry of the alarm warning device, it may affect the operation to respond to a fire condition and will void the manufacturer’s warranty.