How To Use Your Transceiver - PRESIDENT Ronald 10 Owner's Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 17
- Put the switch on the SWR meter to position FWD (calibration).
- Press the PTT switch (10) to transmit.
- Bring the index needle to t by using the calibration key.
- Change the switch to position REF (reading of the SWR level).The reading on
the Meter should be as near as possible to 1. If this is not the case, re-adjust
your antenna to obtain a reading as close as possible to 1 (an SWR reading
between 1 and 1.8 is acceptable).
- It will be necessary to re-calibrate the SWR meter after each adjustment of
the antenna.
You can check at any time the SWR reading using the SWR function. See
page 24.
Warning: In order to avoid any losses and attenuations in cables used for
connection between the radio and its accessories, PRESIDENT recommends
to use a cable with a length inferior to 3 m / 118,11".
Your transceiver is now ready for use.
B) HOW TO USE YOUR TRANSCEIVER
1) ON/OFF ~ VOLUME
Turn on
radio: turn VOL knob (1). If the function KEY BEEP is active (see page
22), the radio emits a beep. The radio is "on".
Turn Off
radio: counterclockwise turn VOL knob (1) until radio emits click
sound. Your radio is "off".
Volume
Adjustment: clockwise rotate VOL knob (1) to adjust volume. Turn
the same knob anti-clockwise to reduce the sound level.
2) ASC (Automatic Squelch Control) ~ SQUELCH
Suppresses
undesirable background noises when there is no communication.
Squelch does not affect neither sound nor transmission power, but allows a
considerable improvement in listening comfort.
a) ASC: AUTOMATIC SQUELCH CONTROL
Worldwide patent, a PRESIDENT exclusivity.
Turn the SQ knob (2) anti-clockwise into ASC position.
No repetitive manual adjustment and a permanent improvement between
the sensitivity and the listening comfort when ASC is active. This function can
be disconnected by turning the switch clockwise. In this case the squelch
adjustment becomes manual again.
b) MANUAL SQUELCH
Turn the SQ knob (2) clockwise to the exact point where all background
appears on LCD.
disappears from LCD.
noise disappears. This adjustment should be done with precision as, if set to
maximum (fully clockwise), only the strongest signals will be received.
3) EMG 1/2 ~ ECHO
EMG 1/2
(short press)
Press EMG 1/2 key (3) to
activate
select
press to
the first programmed priority channel, second press to select
the second programmed priority channel, third press to go back to current
channel, "EMG" disappears from LCD.
The default priority channels are channel 9 and channel 19.
See menus EMG SET 1 and EMG SET 2 page 23 for the PRIORITY CHANNEL
configuration.
ECHO
(long press)
Long press ECHO key (3) to
"
" during 3 seconds.
/
See menu ECHO SET page 23 for ECHO configuration.
4) SCAN ~ DW
SCAN
(short press)
Press SCAN key (4) to
enable
SCAN function. "
stops as soon as there is a busy channel. In
knob (5) or UP/DN keys (11) on the microphone to change scan direction.
Press SCAN key (4) again or PTT switch (10) to exit SCAN. "
from LCD.
See § SCAN TYPE page 24 for configuration of the SCAN type.
DW (Dual Watch)
(long press)
This function
allows
to survey between programmed channel and the current
channel.
Press DW key (4) to
enable
DUAL WATCH function. "
Press DW key (4) again or PTT switch (10) to exit DUAL WATCH function.
"
" disappears from LCD.
See menu DW SETTING page 24 for the DUAL WATCH channel configuration.
5) ROTARY "PUSH" KNOB
In
POWER ON
mode, turn rotary PUSH knob (5) to adjust frequency. Clockwise
to increase, counterclockwise to decrease.
If SPAN function is active, a short press on PUSH knob (5) permits to
frequency continuously (see menu SPAN page 24).
20
priority Channels. "EMG" blinks on LCD. First
enable/disable
ECHO function. LCD shows
" blinks on LCD. The scanning
SCANNING
mode, press PUSH
" disappears
" blinks on LCD.
adjust

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ronald 12m

Table of Contents