Understand indicator light of air quality ..............11 Disassembly and installation methods of the front panel........12 CONTENTS Placement of air purifier..................13 Install filter net......................14 Understand functions of the filter net..............17 4. How to use.......................22 Function description of control panel..............22 Start the air purifier....................22 Manual adjustment of wind speed................23 Timer mode......................24 Filter net reset and anion mode................24 Maintenance and cleaning methods...............26 Clean the air purifier....................26 ...
Page 3
ve been given supe ervision or instruc tion concerning us se of the appliance e in a safe Fittings s........................40 ay and 7. Other i nformation................ ......41 derstand the haza rds involved. Child dren shall not play with the applianc e. Cleaning d user Recyclin ng.................. ......41 aintenance shall no ot be made by chil dren without supe ervision. 8. Warran nty description..
Page 4
Please insert t the plug fully into o power socket b before starting th he air Attention purifier. ease turn off powe er of the machine if any of the follow wing conditions o ccurs: Electric sh hock or overheati ng, even fire acci dents may occur if the plug is not ...
Page 5
The room must t be ventilated wh hen using this air purifier together with Product intro oduction the electric hea ater. Indicat tor light of air qual lity Or, carbon n monoxide poison ning may happen. This air purifier is unab ble to eliminate car rbon monoxide. Prohibited to use this air pu urifier in the ro oom with fumig ation pesticides. Air inlet (both sides Chemical ...
Function description of control panel Control panel Air quality sensor HEPA efficient filter net Front panel Activated carbon filter Indicator light of air quality Color Air quality Pre-filter net Blue Good Green Ordinary Red Poor ...
sassembly and i installation met thods of the fron nt panel 3.Befo re use Disassembly meth hod of the front pa anel Record d date of use on th he label ld groove at two s sides of the front p panel, pull out the magnetic door ho lder. Slightly Please rec cord date on nam meplate at back of f the machine bod dy before using th his air lift up the bottom of groove to remove e the front panel.
Placeme ent of air purifie r stall filter ne et In order to o provide your roo om with good circu ulation, please ma ke sure there is at least formation: 50 cm sp ace between air i nlets at both side es of every machi ne and wall surfa ce or curtain. A And please make s sure space betwee en air outlets and the back is at lea ast 10 is air purifier is in clusive of all filter r nets. Please rem move packings of a...
Page 9
2. Hold groove at two sides of the front panel, pull out the magnetic door holder. 5. Put the filter assembly back into the purifier. Slightly lift up the bottom of groove to remove the front panel. 6. Put the filter assembly back into the purifier, and reinstall front panel. 3.Remove the filter assembly inside the purifier. (Tips: Remove the filter assembly follow the arrow direction). 4.Remove the bag on filter net. ...
Understand functions of the filter net 4‐level filtering efficiently purifies air, to create a healthier life. Composition of the filter net Level 1: Pre‐filter net Level 2: Activated carbon filter net Level 3: HEPA efficient filter net Level 4:Anion function Level 1: Pre‐filter net The micron filter net efficiently prevents fiber particles > 0.2 mm, with preventing rate > 99.9.0%. Easy disassembly and cleaning, and usable for tens of thousands of times. Function: Prevent large particles in air, such as hair, dandruff, coarse particles and fine dust. Prolong life span of the filter net. Activated carbon filter net Level 2: Activated carbon filter net ...
Page 11
vel 4: Anion functi ion ion can induce re eduction of reactiv ve oxygen species s (oxygen free rad icals) in the mospheric pollutan nts, nitrogen oxide es and cigarettes etc., minimizing t heir harmto man body. It can also neutralize th he positively charg ged ...
How to use Allergens nction description n of control panel Hazardo Dandruf Hair particle tive Polle Pet hai Cigarett n and off of the air purifier st mite Chemi ical substance Foul s smell Bacteria east Virus Mycet tic spore Mildew teria ...
After plugged in the power, LED light and buzzer will conduct self‐checking. The *Press FAN SPEED button to enter the manual mode when the product works under indictor light of “POWER ON/OFF” and SPEED OPTION will be on, after pressing the auto mode, silent mode. ON/OFF on the control panel of the product. The air purifier will start work and the *Press FAN SPEED button and choose the SILENT MODE. The wind speed will be at indicator light of air quality will be on with blue color. ...
a. When the machine starts sending out beeping sound, and the filter net reset 5. Maintenance and cleaning methods indictor light flashes with red color, it reminds you to replace the filter nets. When Pull out the power plug before cleaning. finished replacing the filter nets, please press the filter net reset button for a few Please do not put the product in water or any liquid. ...
Clean pre‐filter net ATTENTION: Condensed water may be formed on the air quality sensor when humidity in the room Information is extremely high. Therefore, indicator light of air quality will display poor air quality To achieve the optimum performance, it is recommended to wash and maintain the even if the air quality is good. In this case, please clean the air quality sensor or use any of the manual speed set. filter net every two months (about 480 hours) after the initial use. 1. Use a soft brush to clean air inlet/outlet of the air purifier. * Based on use of the product at home for 8 hours every day, and 7 days one week in average. For exterior maintenance, wipe surface with a piece of wet cloth or mild cleaning agent to prevent dust accumulation. Please turn off the power and pull out the plug during cleaning and maintenance. 2. Dismount protective cover of the air quality sensor. Only pre‐filter nets are washable, other filter nets are not washable. ...
Page 16
Operatin ng steps: 4. Remove particles w with soft brush or r vacuum cleaner. C Clear the filter net t with water 1. Turn of ff the power to sto p the air purifier. d mild soap‐suds a and put the filter n net into machine af fter it is completel y dry. 2. Unplug the power plug. 5.In nstall the filter ass sembly. ...
Page 17
6.Reinstal l the front panel hange compo ound filter ne et formation hen the machine is s starts sending ou ut beeping sound, a and filter replacem ment dicator flashes , it i s to alert the user to replace the cor rresponding filter. 7.Insert p ower plug. 1. When the tot tal ...
Page 18
HIN NT: Please rem move plastic packi ng of each filter n et before putting t them into the mac chine, and make e sure the label of f filter net on one si de is facing upwar rd. Operat ting steps: 1. The ma achine prompts to replace the filter n net. Remove the filter n nets. 2. Turn th e power off to sto p the air purifier. T Then unplug the po ower plug. Remove all the p package for the n ew ...
Page 19
on the control panel. . 6. Install t the filter nets 7. Reinsta ll the front panel. ong‐term idlin ng plug the power pl ug. ( Power is cons sumed even under r ready mode.) oroughly wipe inte erior dry. (Equipme ent fault can be ca used by rustiness. ) t the machine in a a dry and ventilate ed place. (Placed fl lat or upside down n may cause ults.) 8. Insert p power plug , turn t he power on. uggested freq quency of rep placing the fi...
earlier according to actual operating environment. The machine is not turned Insert the power plug and restart the on. machine. ATTENTION: Electric motor is damaged. Contact customer service center or the Please turn power off and pull out power plug before replacing the filter net. distributor. The machine is put on Move the machine to a flat and stable 6. Fault handling The fan does uneven surface. surface. This chapter lists out possible faults when using this product. If faults could not be not work. ...
Poor Air inlet or air outlet of the Contact customer service center or the Warranty and service performance machine is blocked. distributor. If you want to know more information or have any questions, please contact TCL or not Did not remove plastic Remove plastic packing of each filter customer service center or the distributor. achieving the packing of each filter net. ...
Page 22
7. Othe er informatio on Recyc cling Please do o not disgard this product together with other house hold garbage. Find d out your local regulations of dis posing electrical a nd electronic prod ducts. Proper lit ttering of used products can av void potential ad dverse impact on n the environm ent and human. 42 2...