In the TRAP TYPE box select the message type desired, trap or inform. If inform is selected, the
timeout the agent waits (if no answer from the manager) before re-send the inform message can be
set in the INFORMS TIMEOUT box, the number of inform retransmission can be set in INFORMS
RETRIES box.
The messages trap/inform have to be enable and can be enable singly. The enable is provided to the
OIDs (fmSTEventEnable folder):
EVENT
fmSTTransmitterOpModeEventEnable
fmSTRFPresentEventEnable
fmSTFaultEventEnable
fwSTWarningEventEnable
fmSTLocalModeEventEnable

8.3.3 COMMANDS AND STATE

Commands and State available through SNMP are summed in the following table:
EVENT
fmSTTransmitterOpMode
fmSTRFPresent
fmSTFault
fwSTWarning
fmSTLocalMode
The commands are accepted by the unit only in remote mode and if the community strings are
correctly set for both read and write operations.
The community read/write strings have to be set both to the agent and manager units. In the
webpage can be set in the Administration menu.
.1.3.6.1.4.1.19831.1.1.3.1.2.1.1
.1.3.6.1.4.1.19831.1.1.3.1.2.1.2
.1.3.6.1.4.1.19831.1.1.3.1.2.1.3
.1.3.6.1.4.1.19831.1.1.3.1.2.1.4
.1.3.6.1.4.1.19831.1.1.3.1.2.1.5
OID
.1.3.6.1.4.1.19831.1.1.3.1.1.1
.1.3.6.1.4.1.19831.1.1.3.1.1.2
.1.3.6.1.4.1.19831.1.1.3.1.1.3
.1.3.6.1.4.1.19831.1.1.3.1.1.4
.1.3.6.1.4.1.19831.1.1.3.1.1.5
OID
TYPE
Read and Write
Read only
Read only
Read only
Read only
DESCRIPTION
1=Enable, 2=Disable
1=Enable, 2=Disable
1=Enable, 2=Disable
1=Enable, 2=Disable
1=Enable, 2=Disable
DESCIPTION
1=ON, 2=OFF
1=Present, 2=Not Present
1=Fault, 2=No Fault
1=Warning, 2=No Warning
1=Local, 2=Remote