fadini Elpro 27 Instruction Manual

For sliding gate operators with limit switches, s-phase 230v 50/60hz single or double gates
Hide thumbs Also See for Elpro 27:

Advertisement

I
PER APRICANCELLI
pag. 2, 3, 4, 5, 6, 7
GB
FOR
GATE OPERATORS
F
POUR OUVRE-PORTAILS
D
FÜR
I
PER APRICANCELLI A
pag. 2, 8, 9, 10, 11, 12
GB
FOR
F
POUR OUVRE-PORTAILS A
D
FÜR
6893
Dis. N.
Programmatore elettronico con condensatori motore incorporati; idoneo per
27
I
cancelli battenti a una o due ante, con o senza finecorsa e per cancelli
scorrevoli a una o due ante (max. 0,5 CV con frizione meccanica).
Electronic control box with incorporated motor capacitors; suitable for
GB
oil-hydraulic, single or double swinging gates, with or without limit switches and
for single or double sliding gates (max. 0.5 HP with mechanical clutch).
Programmateur électronique avec condensateurs moteur incorporé; adapté pour
F
ouvre-portails a battant avec 1 ou 2 vantaux, avec ou sans fin de course et pour
ouvre-portail coulissants avec 1 ou 2 vantaux (max. 0,5 CV avec embrayage mécanique).
Elektronische Steueurung mit eingebauten Motor-Kondensatoren; geeignet für
D
ein-oder zweiflügeligen Drehtore, mit oder ohne Endschaltern und für ein-oder
zweiflügeligen Schiebetore (max. 0,5 PS mit mechanischer Kupplung).
pages 13, 14, 15, 16, 17, 18
pages 24, 25, 26, 27, 28, 29
Seite 35, 36, 37, 38, 39, 40
MONOFASE 230V 50/60Hz
ACTUATORS, S-PHASE 230V 50/60Hz
pages 13, 19, 20, 21, 22, 23
pages 24, 30, 31, 32, 33, 34
ANTRIEBE EINPHASIG 230V 50/60Hz
Seite 35, 41, 42, 43, 44, 45
meccanica
FADINI
MONOFASE 230V 50/60Hz
, S-PHASE 230V 50/60Hz
MONOPHASE 230V 50/60Hz
EINPHASIG 230V 50/60Hz,
MONOPHASE 230V 50/60Hz
Via Mantova 177/A - 37053 Cerea (VR) Italy
Tel. +39 0442 330422 r.a. - Fax. +39 0442 331054
e-mail: info@fadini.net - www.fadini.net
DIP-SWITCH B
ON
OFF
1
DIP-SWITCH B
ON
OFF
1
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Elpro 27 and is the answer not in the manual?

Questions and answers

Summary of Contents for fadini Elpro 27

  • Page 1 DIP-SWITCH B FÜR ANTRIEBE EINPHASIG 230V 50/60Hz Seite 35, 41, 42, 43, 44, 45 Via Mantova 177/A - 37053 Cerea (VR) Italy meccanica 6893 Dis. N. Tel. +39 0442 330422 r.a. - Fax. +39 0442 331054 FADINI e-mail: info@fadini.net - www.fadini.net...
  • Page 2 - The control box must be installed in a dry and sheltered place; suitable holes are provided with the FADINI universal box for fitting purpose and in case any commercial box is used, this must be adequate to the job - Make sure that power supply to the control board be 230V ±10%...
  • Page 3 UNIVERSAL ELECTRONIC CONTROL BOX meccanica FADINI SINGLE-PHASE 230V 50/60Hz DIP-SWITCH - B FOR SLIDING GATE AUTOMATIC SYSTEMS WITH LIMIT SWITCHES: Dip Switch B N°1= ON 2 3 4 DIP-SWITCH - A Photocells stop gate in opening Radio, no reversing in opening...
  • Page 4 UNIVERSAL ELECTRONIC CONTROL BOX meccanica FADINI SINGLE-PHASE 230V 50/60Hz SAFETY EDGES The two inputs, that are fitted to control the safety edges, are separated for the opening and closing phases. Also, it is possible to select the type of contact connected to them, either N.C. mechanical or 8,2 k resistive, by means of the two jumpers JA1 or JA2.
  • Page 5 UNIVERSAL ELECTRONIC CONTROL BOX meccanica FADINI SINGLE-PHASE 230V 50/60Hz ELECTRICAL CONNECTIONS ON SLIDING GATE MODE - Dip Switch B n°1=ON Accessory Dip-Switch setting and LED indication of functions Electrical connections 24V output: 12 13 Gate electric lock: Power supply output 12Vac/dc or 24Vac/dc...
  • Page 6 UNIVERSAL ELECTRONIC CONTROL BOX meccanica FADINI SINGLE-PHASE 230V 50/60Hz ELECTRICAL CONNECTIONS ON SLIDING GATE MODE - Dip Switch B n°1=ON Accessory Electrical connections LED indication of functions Power connections Terminals for to Pulin 3 LEDs: the connections of the LEDs of the...
  • Page 7 ON: DSA safety control enabled to connect to this output and select if this function is enabled, ELPRO 27 OFF: DSA safety control disabled checks that all the connected photocell devices are cleared from obstacles and properly working before starting any door/gate movements, otherwise the door/gate is not started.
  • Page 8 UNIVERSAL ELECTRONIC CONTROL BOX meccanica FADINI SINGLE-PHASE 230V 50/60Hz DIP-SWITCH - B FOR SWINGING GATE AUTOMATIC SYSTEMS: set Dip Switch B N°1= OFF 2 3 4 DIP-SWITCH - A Photocells stop gate in opening Stroke reversing pulse in Opening cycle...
  • Page 9 UNIVERSAL ELECTRONIC CONTROL BOX meccanica FADINI SINGLE-PHASE 230V 50/60Hz SAFETY EDGES The two inputs, that are fitted to control the safety edges, are separated for the opening and closing phases. Also, it is possible to select the type of contact connected to them, either N.C. mechanical or 8,2 k resistive, by means of the two jumpers JA1 or JA2.
  • Page 10 UNIVERSAL ELECTRONIC CONTROL BOX meccanica FADINI SINGLE-PHASE 230V 50/60Hz ELECTRICAL CONNECTIONS ON SWINGING GATE MODE - Dip Switch B n°1=OFF Electrical connections Dip - Switch setting and LED indication of functions Accessory 24V Output: 12 13 Gate electric lock: Power supply output 12Vac/dc or 24Vac/dc for an 14 15 15VA max.
  • Page 11 UNIVERSAL ELECTRONIC CONTROL BOX meccanica FADINI SINGLE-PHASE 230V 50/60Hz ELECTRICAL CONNECTIONS ON SWINGING GATE MODE - Dip Switch B n°1=OFF Electrical connections LED indication of functions Accessory Limit switches: are involved, link out terminals = OFF on engaging L.sw. Opening M1 30 - 31 - 32 - 33 - 34.
  • Page 12 ON: DSA safety control enabled connect to this output and select if this function is enabled, ELPRO 27 checks OFF: DSA safety control disabled that all the connected photocell devices are cleared from obstacles and properly working before starting any door/gate movements, otherwise the door/gate is not started.
  • Page 13 Libretto Normative di Sicurezza che la Meccanica Fadini mette a disposizione. GB - Please note that installation must be carried out by qualified technicians following Meccanica Fadini’s Safety Norms Manual. L’installation doit être effectuée par un technicien qualifié suivant le manuel des Normes de Sécurité...

Table of Contents

Save PDF