Button Name
Get Setting
Set Temporarily
Set Permanently
‧Reset Basic Settings on IR-712A
If it is failed to communicate with IR-712A and the record of basic settings is lost, click
this item to open the reset window as shown in Fig. 3-6. The steps of reset are as
follows:
(1) Connect PC to the RS-232 port of IR-712A and click "Open" button in the utility to
open the COM port of PC.
(2) Click Reset button within 3 seconds after cycling the power of IR-712A.
(3) A dialog as Fig. 3-7 shows that the resetting to default values is done. Notice that
the parameters resetting is temporary. Please go to "IR-712A Basic Settings" interface
and click "Set Permanently" button to retain the settings.
(4) Tool
‧Update Firmware to IR-712A
Launch the "Update Firmware Tool". Please refer to section
information.
Description
Get the current basic parameter settings of IR-712A.
Set the settings of IR-712A to the parameters selected in the window
temporarily. Cycling the power will restore IR-712A to previous settings.
Set the settings of IR-712A to the parameters selected in the window. IR-712A
will retain the settings after power cycling.
Figure 3-6 IR-712A reset window
Figure 3-7 Reset to default settings temporarily.
IR-712A Universal IR Learning Remote Module (Ver. 1.3, Aug/23/2016) 21
2.6.1
for more