Hanyoung HX4 Instruction Manual

Hanyoung HX4 Instruction Manual

Digital temperature controller hx series

Advertisement

Digital Temperature Controller
series
HX
INSTRUCTION MANUAL
Thank you for purchasing HANYOUNG product.
Please check whether the product is exactly the same as you ordered.
Before using the product, please read this instruction manual carefully.
Please keep this manual where you can view at any time.

Safety information

Alerts declared in the manual are classified to Danger, Warning and Caution by their criticality.
DANGER indicates an imminently hazardous situation which,
DANGER
if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which,
WARNING
if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which,
CAUTION
if not avoided, may result in minor or moderate injury.
Danger
Do not touch or connect any undesirable conductive part to input-output terminal,
since there is a possibility of electric shock.
Warning
•Please install an appropriate protective circuit on the outside. Malfunction or an incorrect operation may be
a cause of leading to a serious accident.
•Since this product does not have the power switch or a fuse, please install those separately on the outside. (Fuse rating : 250 V 0.5 A)
•To prevent damage or failure of this product, please supply the rated power voltage.
•To prevent electric shock or equipment failure, please do not turn on the power until completing wiring.
•Since this is not explosion-proof structure, please do not use in a place where combustible or explosive gas is around.
•Never disassemble, modify or repair the product. There is a possibility of malfunction, electric shock or a risk of fire.
•Please turn off the power when mounting/dismounting of the product.This is a cause of electric shock, malfunction, or failure.
•If the product is used with methods other than specified by the manufacturer, it may lead to injury or property damage.
•Since there is a possibility of electric shock, please use the product as mounted on a panel while the power is being supplied.
•If it is used with systems, machines and equipment that could lead to a risk of life or property damage, please
implement safety devices and protections for both lives and the applications and plan for preventing accidents.
CAUTION
•The contents of the instruction manual are subjective to change without prior notice.
•Please make sure that the specification is the same as exactly you have ordered.
•Please make sure that the product is not damaged during shipping.
•Please use this product in a place where the ambient operating temperature is 0 ~ 50 ℃ (40 ℃ max, closely installed)
and the ambient operating humidity is 35 ~ 85 % R.H (without condensation).
•Please use this product in a place where corrosive gas (such as harmful gas, ammonia, etc.)
and flammable gas do not exist.
•Please use this product in a place where there is no direct vibration and a large physical impact to the product.
•Please use this product in a place where there is no water, oil, chemicals, steam, dust, salt, iron or
hazardous substances (Contamination class 1 or 2).
•Please do not wipe this product with organic solvents such as alcohol,
benzene or others. (Please use mild detergent instead)
•Please avoid places where excessive amount of inductive interference and electrostatic or magnetic noise occurs.
•Please avoid places where heat accumulation occurs due to direct sunlight or radiant heat.
•Please use this product in a place where the elevation is below 2,000 m.
•Please make sure to inspect the product if exposed to water, since there is a possibility of electric leakage or a risk of fire.
•For thermocouple (TC) input, please use a prescribed compensation lead wire. (There will be a temperature error if a general lead is used.)
•For resistance temperature detector (RTD) input, please use a small resistance of lead wire and the 3 lead wires should
have the same resistance. (There will be a temperature error if the 3 lead wires do not have the same resistance.)
•Please keep the input signal wire away from the power lines and load lines to avoid the effect of inductive noise.
•The input signal wires and output signal wires should be separated from each other.
If it is not possible, please use shielded wires for the input signal wires.
•For thermocouple (TC), please use ungrounded sensors. (There is a possibility of
malfunction of the product by electric leakage, if a grounded sensor is used.)
•If there is a lot of noise from the power line, installing an insulated transformer or a noise filter
is recommended. The noise filter should be grounded on the panel and the wire between
the output of the noise filter and the power of the instrument should be as short as possible.
•It is effective against noise, if the power lines of the product are made twisted pair wiring.
•Please make sure the operation of the product before using, since the product may not
operate as it intends to if the alarm function is not properly set.
•While replacing the sensor, please turn off the power.
•In case of the high frequent operation, such as proportional operation, please use an auxiliary
relay since the life span of the output relay will be shortened if it connects to the load without
the rated margin. In this case, SSR output is recommended.
*For Electromagnetic switch : set cycle time : minimum 20 sec.
*For SSR
: set cycle time : minimum 1 sec.
•Please do not connect anything to the unused terminals.
•Please connect wires properly after making sure the polarity of the terminals.
•Please use a switch or breaker (IEC60947-1 or IEC60947-3 approved)
when the product is mounted on a panel.
•Please install a switch or break near the operator to facilitate its operation.
•If a switch or breaker is installed, please put a name plate that the power is off when the switch or breaker is activated.
•In order to use this product properly and safely, we recommend periodic maintenance.
•Some parts of this product have limited expected life span and aged deterioration.
•The warranty of this product (including accessories) is
1 year only when it is used for the purpose it was intended to under normal condition.
•When the power is being supplied there should be a preparation time for the contact output. Please
use a delay relay together when it is used as a signal on the outside of interlock circuit or others.
•When the user replaces with a spare unit due to product failure or other reason,
please check the compatibility since the operation can be varied by
the difference of setting parameters even though the model name and code are the same.
•Before using a temperature controller, there could be a temperature difference between
PV of the temperature controller and the actual temperature, so please operate the temperature
controller after correcting the temperature difference appropriately.
HEAD OFFICE
HANYOUNGNUX CO.,LTD
1381-3, Juan-Dong, Nam-Gu Incheon, Korea,
TEL:(82-32)876-4697 FAX:(82-32)876-4696 http://www.hynux.com
Suffix code
Model
Code
HX
☐ -
☐ Multi-input and output digital temperature controller
2
48(W) × 96(H) ㎜
3
96(W) × 48(H) ㎜
Dimension
4
48(W) × 48(H) ㎜
7
72(W) × 72(H) ㎜
9
96(W) × 96(H) ㎜
0
Standard
Control output
1
Heating / Cooling (simultaneous control)
0
None
HX2/3/9 option
1
RS485 communication + Heater break alarm (HBA)
0
None
HX7 option
1
RS485 communication + DI 2 contacts (SV2, SV3)
2
RS485 communication + Heater break alarm (HBA)
0
None
HX4 option
1
RS485 communication + DI 1 contact (SV2)
2
RS485 communication + Heater break alarm (HBA)
Part name and function
Name
Number
Process value (PV) Displays the process value in the operation mode.
Set value (SV)
Displays the set value in the operation mode.
Increases the set value or used to move between groups and
Up key
to change an option in a parameter in setting mode.
Down
Decreases the set value or used to move between groups and
key
to change an option in a parameter in setting mode.
Shift key Used to move the position of the digit.
Sets (confirm) the set value, displays the output amount, or set an
option in a parameter in setting mode and moves between the
Set key
parameters in a group. By pressing for 3 seconds, it enters the
display setting mode (setting mode) or returns to the operation mode.
Lights when SV2 is displayed.
Lights when SV3 is displayed.
OUT1 indicator.
Operation
OUT2 indicator.
Indicator
Auto-tuning indicator (blink).
Alarm 1 operation indicator.
Alarm 2 operation indicator.
Hot
Hot key is designated for AT or Manual MV
+
key(run/
configuable in the group of "G.CtL"
stop)
Quick
+
Sets the value: SV1, SV2, AL1, AL2
menu
█ External Contact Input (DI) Selection
3 predetermined set values (temperature values) could be changed with using
ON/OFF of the external 2 contact inputs
OFF (contact input is not used)
External input
contact
selection
No display
(
)
-1-
MA0614E170926
Description
PID Auto-tuning
※ HX9 is
chosen to explain
Description
ON (contact input is used)
External contact input
SV2
Set value 1 display (SV1)
OFF
Set value 2 display (SV2)
ON
Set value 3 display (SV3)
OFF
SV3
OFF
OFF
ON

Advertisement

Table of Contents
loading

Summary of Contents for Hanyoung HX4

  • Page 1: Safety Information

    Digital Temperature Controller series INSTRUCTION MANUAL HEAD OFFICE Thank you for purchasing HANYOUNG product. HANYOUNGNUX CO.,LTD Please check whether the product is exactly the same as you ordered. 1381-3, Juan-Dong, Nam-Gu Incheon, Korea, Before using the product, please read this instruction manual carefully.
  • Page 2: Setting Mode

    █ Control Output Composition HX series is a multi-control-output temperature controller. It can have relay ON/OFF, SSR voltage pulse output, 4 – 20 mA current output as a control output by selecting an option in the parameter. If the option is chosen like below in the output parameter ( ) of the output group ( ) in standard temperature controller 0 : Relay ON/OFF control is as a control output.
  • Page 3: Control Group

    Operation Method  Set value (SV) setting group █ When turn the power ON after completing wiring Available Symbol Parameter Option condition Default (1) After the firmware version of the temperature controller appears for a short period of time, the operation mode is running like the number ①...
  • Page 4: Output Group

     Communication group Alarm type and code Available Pay atteontion in selecting relay type. Using inverse relay ( such as use nomally closed Symbol Parameter Option Default condition instead of nomally open) will not output anything even though the indicator is on. Communication Options for group...
  • Page 5 In order to get better response against disturbance in the steady state, there is usually ② Please use the current transformer (CT) designed by Hanyoung NUX. a large overshoot in the transient state. To reduce this overshoot in the transient state, 2 ③...
  • Page 6: Specification

    Function 13 : Factory reset function Function 11 : Hysteresis type This function is used for parameter values to revert to initial setting values. According to selection of Hysteresis type in ON/OFF control, ON/OFF turning point is as follows: 1 . Select factory reset function (PArA) in control group (G.CtL). ex) HYS.t: Cntr(center) 2 .
  • Page 7 ※ For the instructions of the protocol regarding communication, please refer to the 0311 PID group 1 integral time 0 ~ 6000 sec PID Group Hanyoung protocol instruction manual on Hanyoung Nux homepage(www.hynux.com). 0312 PID group 1 derivative time 0 ~ 6000 sec PID Group 0313 1.MR...
  • Page 8 Appearance, Panel cutout and Connection Diagram (Units : ㎜) OUT1 OUT2 OUT1 OUT2 OUT1 OUT2 ● Appearance OUT1 ● Panel cutout ● Connection Diagram OUT1 OUT2 RTX(+) RELAY OUT1 RELAY RTX(-) OUT1 OUT1 RTX(+) SSR/SCR OUT1 OUT1 OUT2 RTX(+) RELAY OUT1 RTX(-) RELAY...

This manual is also suitable for:

Hx7Hx9Hx2Hx3