Bosch Sensixx B35L Repair Instructions page 13

Hide thumbs Also See for Sensixx B35L:
Table of Contents

Advertisement

6.
Water outlet: This hose takes water from the tank to the
pump, which then drives it towards the boiler.
7.
Ventilation inlet for priming the pump: To avoid the pump
to work in vacuum, at the outlet of the pump there is a safety
overpressure valve. This valve opens when there is a
blockage or overpressure at the entrance of the boiler, and
directs the water back into the tank.
8.
Float: It contains a magnet, to lower the water level, is
approaching a switch Reed (lack of water sensor), which
activates the LED of lack of water.
9.
Without water sensor: Reed switch that closes when float
reaches the bottom of the tank. When the Reed switch closes,
lights the indication of lack of lack of water.
4.1.4
Pump
6
10.
Pump: The pump drives water from the tank into the boiler. It
is activated in two situations:
When the upper boiler NTC (18) detects more than 190ºC
(empty water tank).
When the lower boiler NTC (16) detects more than 170ºC.
214_58300000171747_ARA_EN_A – 01.03.a
10
7
11
Important!
The pump has a diode, so it is important to respect
the polarity of the connections
11.
Hose to water inlet in the boiler
4.1.5
Boiler
Seite 13 von 39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents