4.1.2
Control panel area
1.
LED "Refill water tank": LED that lights when the water tank
float is below a certain level.
2.
LED "Steam ready" / "secure": LED that illuminates when
inside the boiler has reached the proper pressure (when the
boiler NTC detects temperature above 150ºC)
3.
Main switch: The steam station power ON/OFF switch.
4.
ECO function switch: Enables or disables the ECO function
which reduces the temperature inside the boiler and thereby
the overall consumption of the appliance
214_58300000171747_ARA_EN_A – 01.03.a
5.
Steam regulator knob: Knob connected to a potentiometer,
which through the signal that sends to the electronics, controls
the amount of steam that is sent to the iron.
4.1.3
Water tank area
Seite 12 von 39