Advertisement

Quick Links

Table of Contents

Table of Contents ......................................................................... 1
Introduction ................................................................................. 1
Specifications ............................................................................... 3
F-940 Specifications ..................................................................... 3
Unpacking the F-940 Store It! ...................................................... 5
Operating Instructions ................................................................. 6
Loading the Battery ................................................................. 6
Basic Operation ........................................................................ 7
Measurement Modes .............................................................. 7
Continuous Mode .................................................................... 9
Trigger Mode ........................................................................... 9
Taking a Measurement .......................................................... 10
Passcode Protection .............................................................. 11
Setup Menu ............................................................................... 12
Setup > Mode ......................................................................... 12
Setup > Set Zero ..................................................................... 13
Setup > Calibration ................................................................ 15
Setup > O2 Calibration in Air ................................................. 15
Setup > Date and Time........................................................... 15
Setup > RH Conversion .......................................................... 16
Setup > GPS ............................................................................ 17
Setup > Language ................................................................... 17
File Menu ................................................................................... 18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F-940 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Felix Storch F-940

  • Page 1: Table Of Contents

    Table of Contents Table of Contents ................. 1 Introduction ................. 1 Specifications ................3 F-940 Specifications ..............3 Unpacking the F-940 Store It! ............5 Operating Instructions ..............6 Loading the Battery ..............6 Basic Operation ................ 7 Measurement Modes .............. 7 Continuous Mode ..............
  • Page 2 Wireless SD Memory Card Operation ........22 F-940 Store It! Menu Map ............25 G.A.S. Gas Analysis Software ............26 Firmware Update ...............35 Maintenance of your F-940 Store It! Gas Analyzer ....37 Replacing the Oxygen (O₂) Sensor..........37 Replacing the Potassium Permanganate Filter (KMnO4) ..39 Calibration ................40 Applications ................45...
  • Page 3: Table Of Contents

    F-940 provides a fast, portable verification process for atmosphere quality control. Easy to use straight out of the box with little or no training, the F-940 is ideal for verifying CO levels in Modified Atmosphere Packaging (MAP) applications, laboratories, distribution centers, retail centers, storage facilities, and shipping containers.
  • Page 4 F-940 Instruction Manual rev. 3-8-2017 Features • The F-940 features include: • Measures C2H4, CO2 and O2 • Displays results in under 30 seconds • Past records stored on the device • Handheld and lightweight • Internal data logging and storage •...
  • Page 5: Specifications

    F-940 Instruction Manual rev. 3-8-2017 Specifications F-940 Specifications Air Sampling Rate 70 mL/min Automated, 1 second intervals to SD Measuring Rate in Continuous Mode Data Storage Removable 16 GB SD and Bluetooth Display Sunlight visible transflective LCD 0°C - 50°C (15-90% relative humidity,...
  • Page 6 F-940 Instruction Manual rev. 3-8-2017 Nominal Range 0-100% Full Scale Resolution 0.01% Accuracy – Trigger ±.5% absolute and ±3% of measured Mode value Accuracy – Continuous ±.01% absolute and ±3% of measured Mode value Lower Detection Limit 0.01% Sampling Time...
  • Page 7: Unpacking The F-940 Store It

    F-940 Instruction Manual rev. 3-8-2017 Unpacking the F-940 Store It! The F-940 arrives with a hard-sided carrying case, two sets of batteries and a charger, a removable SD card, and several accessory parts. A sampling port with needle is included for taking non-destructive samples from packaging.
  • Page 8: Operating Instructions

    If the batteries of the F-940 discharge during storage, replace with charged batteries and allow the instrument to stabilize 48 hours before use.
  • Page 9: Basic Operation

    Setup list, use the Right arrow. To File F-940 Vx.x.x.x exit, use the Left arrow. Measurement Modes Two measurement modes are incorporated into the F-940 Store 1554 NE 3 Ave, Camas, WA 98607, USA Phone: (360) 833-8835 sales@felixinstruments.com www.felixinstruments.com...
  • Page 10 F-940 Instruction Manual rev. 3-8-2017  Continuous mode  Trigger Mode Continuous mode measures the air entering through the input of the instrument continuously without stopping. Continuous mode can be used with or without the sample port attached to the front of the instrument. Data is saved to a file every one second on the F-940.
  • Page 11: Continuous Mode

    F-940 Instruction Manual rev. 3-8-2017 Continuous Mode When in continuous mode, a graph of the concentration of each gas can be viewed over time. The default graph shown is the O concentration in ppm. To view the C2H4 or CO graph, simply use the up and down arrows to scroll through the graphs.
  • Page 12: Taking A Measurement

    Taking a Measurement Assemble the probe and connect the needle probe tubing to the intake of the F-940. Twist on a hydrophobic filter to the end of the tubing. The filter will prevent any moisture or debris from entering the instrument. [NOTE: Failure to use a hydrophobic filter risks drawing liquids into the instrument, which can potentially damage the instrument sensors.] Finally, attach a...
  • Page 13: Passcode Protection

    (trigger mode). Press the Left arrow button to return to the measurement screen. Passcode Protection Certain menu systems on the F-940 are protected by a passcode setting. These menu systems include Parameters, Set Zero, Calibration, and Factory Setup. The default code for entry is ‘1111’.
  • Page 14: Setup Menu

    F-940 Instruction Manual rev. 3-8-2017 6. Check the box named ‘Show hidden files, folders, and drives’ 7. Click ‘Yes’ 8. Click ‘Apply’ and then click ‘OK’ 9. Open the Config.txt file that should now appear inside the SD card 10. Alter the ‘1111’ to four-digit numeric passcode desired 11.
  • Page 15: Setup > Set Zero

    F-940 Instruction Manual rev. 3-8-2017 To change, use the Up/Down arrows to cycle through the mode options. Press the Left arrow to exit to the main menu. Mode Measure Trigger Connection USB Storage Setup > Set Zero The set zero process sets a new baseline, or zero, for the...
  • Page 16 The following instructions can be followed to set zero for the CO2 sensor: The F-940 is shipped with an external conditioning tube and a jar of Soda Lime. Fill the conditioning tube with the Soda Lime granules, keeping the ends packed with the cotton ball filters.
  • Page 17: Setup > Calibration

    Unlike Setup > Set Zero in the next section, a zero standard gas is required as well as standard gases for the set span process. The F-940 Store It! Will prompt the user to set up a zero gas, which can be achieved by feeding 100% Nitrogen (N2) gas to the intake.
  • Page 18: Setup > Rh Conversion

    The Setup RH Conversion menu is used to correct for the temperature sensor being inside F-940 housing. This causes the temperature sensor to reflect the temperature of the F-940 and not the ambient temperature, which is usually several degrees above ambient. The Relative Humidity is calculated based on the temperature value.
  • Page 19: Setup > Gps

    F-940 Instruction Manual rev. 3-8-2017 Setup > GPS The GPS sensor inside of the F-940 Store It! can be used to record latitude and longitude +/- 10 meters. The instrument should be operated outside, without overhead obstruction for best GPS performance. The Setup > GPS menu turns on/off the GPS sensor and displays the current GPS data.
  • Page 20: File Menu

    F-940 Store It! File > Select File Select displays a list of .csv files that exist on the F-940 Store It! SD card. Use the Up/Down arrows to move between files, and right arrow to select a file to which new data will be saved.
  • Page 21: File > Create

    SD card. There will be a new file in the list with the current date. File > Delete File Delete displays a list of files that exist on the F-940 Store It! SD card. Use the Up/Down arrows to scroll between files and Delete Data .
  • Page 22: Transferring Files

    When reviewing trigger mode files, the software can support viewing up to 10 records at a time. The data.csv file is the F-940 default file used to store data when no other file is selected. After selecting a file name, the measurement mode with time of the measurement and gas concentration will appear for Trigger mode readings.
  • Page 23 F-940 Instruction Manual rev. 3-8-2017 SD CARD Example spreadsheet data from an F-940 Store It! REMEMBER: Always save the data files to the computer before making changes or starting analysis. *Raw output field designations: Raw C2H4, Raw O2, Raw CO2, CO2 Ref, Zero...
  • Page 24: Wireless Sd Memory Card Operation

    Wireless SD Memory Card Operation These instructions are meant to accompany the instructions supplied by the vendor for Toshiba FlashAir™ W-03 to use specifically with the F-940 Store It! Gas Analyzer, which can be similarly applied to other Felix Instruments products. 1. Install FlashAir™...
  • Page 25 F-940 Instruction Manual rev. 3-8-2017 6. The Wi-Fi card can be enabled in “internet pass thru mode”, outlined in the following documentation provided within the FlashAirTool software: • Go to Network Settings on the main menu Check Internet pass thru mode This function is available for FlashAir™...
  • Page 26 F-940 Instruction Manual rev. 3-8-2017 your smartphone or other device must be changed from the FlashAir™ card to the internet access point. Check the “Enable internet pass thru mode” checkbox to enable “internet pass thru mode”. o Access Point SSID Sets the SSID of the internet access point.
  • Page 27: F-940 Store It! Menu Map

    F-940 Instruction Manual rev. 3-8-2017 F-940 Store It! Menu Map Below is a map of the F-940 Store It! Two Gas Analyzer menu system. Press the right arrow to enter a menu and the Left arrow to exit. Measure Graph View...
  • Page 28: G.a.s. Gas Analysis Software

    B. Install C. Launch the downloaded G.A.S. program There are two ways to connect the F-940 Store It! To the G.A.S. program: Bluetooth or USB cable connection. 1. For USB cable connection, move ahead to step 4. For Bluetooth connection, on your F-940 Store It!, navigate to Setup >...
  • Page 29 F-940 Instruction Manual rev. 3-8-2017 2. Verify that the passcode matches between the F-940 Store It! and the computer, accept each. 3. Once verified, navigate back to G.A.S., the program will initiate a connection with the F-940 Store It! 1554 NE 3...
  • Page 30 F-940 Instruction Manual rev. 3-8-2017 4. Once connected, your device serial number should appear in the upper left hand corner of the window, click on the serial number, you are now ready to interact with the F- 940 Store It! Click on the grey and blue square in the upper right hand corner to dis-connect or re-connect.
  • Page 31 The ‘Control Panel’ menu displays toggle keys which allow the user remote control of the F-940 Store It! The ‘Calibration’ menu navigates the user through the calibration process for both set zero and set span.
  • Page 32 F-940 Instruction Manual rev. 3-8-2017 Just select the file of interest and choose whether to download the file from the device, Or open a saved file from your pc. When the document appears on the right hand column, select it to view and make edits in the 'Note' section.
  • Page 33 Measurement Monitor The Measurement Monitor menu allows the user to view a graphical live feed of measurements taken on the F-940 Store It! This feature will display the measurement mode being used, the selected gas, temperature, flow, and RH with the option to toggle between CO2, O2 and C2H4.
  • Page 34 Control Panel The Control Panel Menu allows the user to control the F-940 Store It! From a computer using a series of toggle keys seen below.
  • Page 35 F-940 Instruction Manual rev. 3-8-2017 Each sensor will require its own standard gas for calibration. After the set span is complete it is best practice to verify your calibrations were successful by reading the standard gas to ensure accuracy. Settings G.A.S.
  • Page 36 F-940 Instruction Manual rev. 3-8-2017 The user has the flexibility to create a customized validation profile, creating unique profile names and threshold values for each gas of interest, useful for quality monitoring! Simply "apply validation profile" created after selecting your customized validation profile, and then proceed to see your results in the Measurement Monitor display.
  • Page 37: Firmware Update

    F-940 Instruction Manual rev. 3-8-2017 Firmware Update To update the firmware on the F-940 Store It!, you will need to download and install G.A.S. as outlined in the previous section. Launch the software, connect your device and select “Help”. This will reveal a menu with the option to update your firmware.
  • Page 38 F-940 Instruction Manual rev. 3-8-2017 Once “Upgrade Device Firmware” is selected, the software will outline a series of steps for the upgrade. Follow the instructions provided in steps 1 and 2, step 3 requires the selection of a .dfu file, which can be downloaded from: https://felixinstruments.com/support/F-940/software/...
  • Page 39: Maintenance Of Your F-940 Store It! Gas Analyzer

    Felix Instruments contact sales@felixinstruments.com. To replace the sensor refer to images on following page: 1. Turn off the F-940 Store It! and remove the bottom rubber mat. 2. Remove the battery cap (it’s spring loaded!) and unscrew the black bottom plate of the F-940.
  • Page 40 F-940 Instruction Manual rev. 3-8-2017 3. Unplug the red and black cable connector by gently pulling the fastener out the end of the O₂ sensor. 4. Unscrew the O sensor (counter-clockwise). 5. Screw in the new sensor (clockwise) until you feel a resistance—not too tight!
  • Page 41: Replacing The Potassium Permanganate Filter (Kmno4)

    The small black jar is the KMnO4 filter, just unscrew the bottom plate of the F-940 unit after removing the battery cap, unscrew the filter, screw in the replacement and you’re done! Screw back into place the bottom plate and finally the battery cap.
  • Page 42: Calibration

    The F-940 allows the user flexibility with calibrating, there are two methods for calibrating: utilizing the computer-free calibration method through on-device adjustments under Setup > Calibration on the F-940, OR by using the computer software program: G.A.S. (Gas Analysis Software). The G.A.S. Calibration menu also enables a two-point calibration process for the F-940 Store It! Including Zero Calibration and Span Calibration.
  • Page 43 F-940 Instruction Manual rev. 3-8-2017 Set zero should take place weekly for all sensors to maintain maximum performance. The set zero process does not require G.A.S. and can be done following the processes outlined in the “Setup > Set Zero” section of the user manual. Set zero optionally CAN be done with G.A.S.
  • Page 44 If you have already completed the set zero process, press "Ok". Another prompt will appear asking the user to put the device in Continuous Monitor mode (On the F-940 Store It!: Setup > Mode > Measure > Continuous). Then navigate to the main menu and begin measuring.
  • Page 45 F-940 Instruction Manual rev. 3-8-2017 Press "Ok". The G.A.S. software will begin the calibration process and count down. Once the calibration is completed, a green verification can be seen above the start button. Following step 6 of the instructions listed, you should now verify the calibration was successful by taking a reading of the standard gas used in the process.
  • Page 46 F-940 Instruction Manual rev. 3-8-2017 It is highly recommended that this step be performed after one full day has passed since the calibration was performed. If this step is not performed, accuracy of the calibration cannot be verified. Connect and read each gas and record the results here after three minutes (at least) of measure time.
  • Page 47: Applications

    By creating a closed loop, the rigid jar will not pressurize by the displaced sample gas removed from the jar. The gas will be drawn into the F-940, analyzed by the sensor, and then re-circulated back into the jar through the closed-loop sample probe.
  • Page 48: Polarcept

    F-940 Instruction Manual rev. 3-8-2017 PolarCept It is recommended to use the external PolarCept filter when measuring a mixture of gas (such as when sampling fruit) or interfering gases may be reported by the instrument. The PolarCept filter is recommended for Trigger Mode.
  • Page 49 F-940 Instruction Manual rev. 3-8-2017 VOC concentration PolarCept saturation (min) 3 ppm 100 ppm To fill the PolarCept filter, attach an empty syringe to the hydrophobic filter. The plunger of the syringe should be completely depressed. Lower the PolarCept over a cup of distilled water and draw in 1.5 mL with the syringe.
  • Page 50: F-940 Production Test Check Sheet

    F-940 Instruction Manual rev. 3-8-2017 F-940 Production Test Check Sheet SERIAL NUMBER: Firmware Version: NOTES: 1554 NE 3 Ave, Camas, WA 98607, USA Phone: (360) 833-8835 sales@felixinstruments.com www.felixinstruments.com...
  • Page 51: Guide For Purchasing Standardized Gases For Calibration

    Below is an example of a standard order our company would make to Air Liquide for a 1.5ppm ethylene standardized gas tank for calibration of the F-940. 1554 NE 3 Ave, Camas, WA 98607, USA Phone: (360) 833-8835 sales@felixinstruments.com...
  • Page 52 Air Liquide America Specialty Gasses LLC Telephone 425-931-8303 or 800-814-4642 A sample order for 34 Liter canister of appropriate calibration gas for an F-940 or F-950 would include the following (Note, these are Air Liquide’s unique product numbers): Part Number:...
  • Page 53 F-940 Instruction Manual rev. 3-8-2017 gas showing what they have delivered. Be certain to use the actual value on the certificate of analysis as it may differ from what you have ordered. If you don’t already own a regulator, you must buy one. The following is the ordering information for the on-demand style regulator that we typically use.
  • Page 54: Warranty Information

    F-940 Instruction Manual rev. 3-8-2017 Warranty Information Seller's Warranty and Liability: Felix Instruments- Applied Food Science warrants new equipment of its own manufacturing against defective workmanship and materials for a period of one year from date of sale. The results of ordinary wear and tear, neglect, misuse, accident and excessive deterioration due to corrosion from any cause is not to be considered a defect.
  • Page 55 F-940 Instruction Manual rev. 3-8-2017 Please contact Felix Instruments technical support department at support@felixinstruments.com to obtain an RMA number before shipping instrument to CID Bio-Science, Inc. Buyer is responsible for shipping charges to Felix Instruments headquarters: 1554 NE 3rd Ave.
  • Page 56: Warranty Registration Card

    F-940 Instruction Manual rev. 3-8-2017 Warranty Registration Card 1554 NE 3 Ave, Camas, WA 98607, USA Phone: (360) 833-8835 Fax: (360) 833-1914 e-mail: sales@felixinstruments.com Web: www.felixinstruments.com PRODUCT REGISTRATION CARD Please complete and return this form to Felix Instruments within 30 days to validate your Warranty on Parts & Labor.

Table of Contents