G3PX
Item
Min. phase detection
---
Min. phase setting
---
Min. load current for
---
ON error detecting
Abnormality detection
---
time
Voltage drop with
1.6 V max. (RMS)
output ON
Leakage current
10 mA max. at 100/110 VAC, 20 mA max. at 200/230 VAC
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min.
Vibration resistance
Malfunction: 10 to 55 Hz, 10G
Shock resistance
Malfunction: 300 m/s
Ambient temperature
Operating: –25 C to 65 C (with no icing or condensation)
Storage:
Ambient humidity
Operating: 45% to 85%
Weight
G3PX-220EUN: approx. 1.1 kg
G3PX-240EUN: approx. 1.4 kg
G3PX-260EUN: approx. 1.7 kg
Note: 1. Duty setting does not complete to the OFF state (i.e. 10% remains).
2. The start-up time is factory-set to 1 s on the EH Series, approx. 0.5 s on the EHN and EC Series.
3. This is the initial start-up time with a 100% duty setting.
4. Detection is effective when the set current is reduced by 20% or more.
5. The minimum set value in the G3PX-220EHN is 6 A. If a lower value is required, increase the number of wiring turns around the CT.
EC Series
Item
Operating voltage range
Operating frequency range
Output voltage adjustable
range
Internal duty setting range
External duty setting range
Start-up time
Min. load current for ON error
detecting
Current limit range
Excess current detection
Constant current
Abnormality detection time
Voltage drop with output ON
Leakage current
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Weight
4
G3PX-220EUN/
240EUN/260EUN
Approx. 1/6
---
1 A
0.1 s max.
2
–10 C to 55 C (with no icing or condensation)
G3PX-220EH: approx. 1.1 kg
G3PX-240EH: approx. 1.4 kg
G3PX-260EH: approx. 1.7 kg
G3PX-220EC
10%
1 Hz
0% to 95%
0% to 100%
0% to 100%
Approx. 0.5 to 10 s
20% max. of rated current
0% to 100%
Peak current of 110 A within
1 cycle
3% max. with 10-time increment of load value
3% max. with 10% change of voltage
1 s max.
1.6 V max. (RMS)
10 mA max. at 100/110 VAC, 20 mA max. at 200/220 VAC
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min.
Malfunction: 10 to 55 Hz, 10G
2
Malfunction: 300 m/s
Operating: –25 C to 65 C (with no icing or condensation)
Storage:
–10 C to 55 C (with no icing or condensation)
Operating: 45% to 85%
G3PX-220EC: approx. 1.1 kg
G3PX-240EC: approx. 1.4 kg
G3PX-260EC: approx. 1.7 kg
G3PX-220EH/240EH/260EH
π
G3PX-240EC
Peak current of 220 A within
1 cycle
G3PX
G3PX-220EHN/
240EHN/260EHN
π
Approx. 1/6
30% max. of rated current
(see note 5)
1 s max.
G3PX-220EHN: approx. 1.2 kg
G3PX-240EHN: approx. 1.5 kg
G3PX-260EHN: approx. 1.8 kg
G3PX-260EC
Peak current of 330 A within
1 cycle