11.2 ALARM I/O Connection & Operation
3 Sensor Activated Alarm
The unit is equipped with 4 alarm sensor inputs. If any alarm is activated:
the built-in buzzer will be activated.
the quad will switch the corresponding channel indicator LED to blinking mode.
a warning message depending on different models will be displayed as follows:
Quad output channel (#4)
Alarm
Blinking Alarm & Title message on the
activated channel in quad screen
Above mentioned alarm can be cleared by: If the device is operated under Security Lock ON mode, Push Lock button for
2 seconds to disable the function then push any button in the front panel.
4 Video Loss Alarm
Loss of video at any input is automatically detected by the device. The device will:
Activate the built-in buzzer.
Switch the corresponding channel indicator LED to blinking mode.
Display warning message on quad screen:
Quad output channel (#4)
Video loss
Blinking Video Loss & Title message
on the activated channel in quad
screen
LIVE output channel (#5)
Full screen display of the activated channel.
Also display a blinking Alarm message
The warning message and the buzzer can be cleared
by pushing Lock button (#2) for more than 4 seconds if the
device is operated under Security lock On mode, or pushing
any button on the front panel if the device is operated under
Security lock OFF mode.