If a device fails the system exerciser tests, the system displays the following:
KA45/47 V1.0
System Test CU
3
DZ #
9
NI #
10
SCSI #
12
COMM #
1
2
3
4
?? 14
ASYNC 40
***** SYT_DISPLY_SUMRY (('1'=Y), ('0'=N))................... ?
Error Report—The error report replaces the status bar when a device fails
1
the system exerciser tests. Two question marks (??) indicates a hard error,
that is, an error that you must correct before booting the system. One
question mark (?) indicates a soft error, that is, an error that you do not
have to correct before booting the system.
Device Number.
2
Device Mnemonic.
3
Field Replaceable Unit (FRU).
4
Error Message.
5
Elapsed Time—The time elapsed since the test started.
6
A prompt for the summary screens (see Section 1.2.5). Enter 1 to display
7
the summary screens; enter 0 to return to the console prompt.
If you see an error report, write it down. Then contact your Digital Services
representative (see Section 1.3).
5
6
0305
0 00:01:26
Troubleshooting and Diagnosing Problems 1–17