ECOSTAR ECO 8 NG Installation, Operating And Maintenance Manual

ECOSTAR ECO 8 NG Installation, Operating And Maintenance Manual

Monoblock heavy oil burners

Advertisement

MONOBLOCK HEAVY OIL BURNERS INSTALLATION,
OPERATING AND MAINTENANCE MANUAL
MODULATING OPERATION
ECO 8 NG
ECO 9 NG
www.ecostar.com.tr

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECO 8 NG and is the answer not in the manual?

Questions and answers

Summary of Contents for ECOSTAR ECO 8 NG

  • Page 1 MONOBLOCK HEAVY OIL BURNERS INSTALLATION, OPERATING AND MAINTENANCE MANUAL MODULATING OPERATION ECO 8 NG ECO 9 NG www.ecostar.com.tr...
  • Page 2 DEAR USER, ECOSTAR EC0 8 NG, ECO 9 NG Heavy Oil burners are prepared and manufactured according to the latest technical developments and safety rules. It is easy to use for our customers. We recommend that you read this manual and safety warnings thoroughly before the use of the device in order to ensure safe, cost effective and environmental-friendly use.
  • Page 3: Table Of Contents

    CONTENTS WARNINGS ............................... 3 Warning Symbols and Descriptions ......................3 General Safety Rules ..........................4 TERMS OF WARRANTY ......................... 6 Out of Warranty Conditions ........................6 BURNER’S GENERAL FEATURES ......................7 Purpose of Use and Work Limits of Burners ..................7 Code Key ..............................
  • Page 4: Warnings

    WARNINGS Warning Symbols and Descriptions Symbols Symbol Descriptions Important information and useful hints. Warning of danger to life or property. Warning of electrical voltage. Product handling information. Electric motor direction of rotation Carry in an upright position. Fragile Item. Protect against water. 13.06.2017 Rev.
  • Page 5: General Safety Rules

    General Safety Rules • All personnel engaged in installation, disassembly, commissioning, operation, control, maintenance and repair should have received the necessary training and fully read and understood this manual. • No changes that might damage the safety of the burner unit must be made by persons and/or organizations on the burner unit.
  • Page 6 The burner installation must be carried out in accordance with the instructions. Vibration can damage the burner and its components. Keep boiler doors closed while starting burner and during burner operation. Check combustion values to be correct by using flue gas analysis at the whole adjustment range between minimum, full load, and ignition load.
  • Page 7: Terms Of Warranty

    TERMS OF WARRANTY Main and auxiliary equipment and all components used in Ecostar Heavy Oıl burners are guaranteed for 1 year by TERMO ISI SİST. A.Ş starting from the date of commissioning under the maintenance, adjustment, operating conditions and relevant mechanic, chemical and thermal effects explained herein.
  • Page 8: Burner's General Features

    BURNER’S GENERAL FEATURES ECOSTAR Heavy Oil burners are designed to operate with oil at 2.5 – 20 Cst (mm²/s) viscosity, at rated capacity and pressure ranges and -15% to +10% nominal voltage. Purpose of Use and Work Limits of Burners •...
  • Page 9 Temperature change of fuel used in ECOSTAR heavy oil burners dependent on viscosity 13.06.2017 Rev. 01...
  • Page 10: Technical Data

    TECHNICAL DATA Capacity and Technical Chart NEW GENARATION MODULATING HEAVY-OIL BURNERS CAPACITY TABLE HEAVY OIL FAN MOTOR MAIN BURNER TYPE CAPACITY CAPACITY CONSUMPTION POWER SUPPLY Min. Max. Min. Max. Min. Max. kcal/h kcal/h kg/h kg/h ECO 8 O(S) C 3 NG 722.400 5.160.000 6.000...
  • Page 11: Back Pressure-Capacity Diagrams

    Back Pressure-Capacity Diagrams 13.06.2017 Rev. 01...
  • Page 12: Outer Dimensions

    Outer Dimensions 13.06.2017 Rev. 01...
  • Page 13: Flame Length And Diameter

    Flame Length and Diameter 13.06.2017 Rev. 01...
  • Page 14: Installation

    INSTALLATION Burner Installation Picture Fuel Pumping Station Interconnection of pressure transmitters 13.06.2017 Rev. 01...
  • Page 15: Commissioning

    COMMISSIONING General Controls Electrical Connection Perform electrical connections according to the diagram provided with the burner. Follow general security rules during installation of electric wiring and making connections. Connect the earthing terminal in electric panel to the earthing installation. Make sure to perform the following controls before commissioning the burner. Ø...
  • Page 16: Combustion Adjustment

    Combustion Adjustment Ø Photocell Check the photocell weekly. Clean the dust or fume stains on the glass of photocell by a dry cloth. Fuel Pumps MF Type 13.06.2017 Rev. 01...
  • Page 17 TA Type 1. Suction 2. Nozzle outlet 3. Return 4. Manometer inlet 5. Vacuum or inlet manometer and internal return inlet 6. Pressure adjustment 7. Pre heater location 13.06.2017 Rev. 01...
  • Page 18 Ø Modulating Heavy Oil Burner Fuel Circuit 13.06.2017 Rev. 01...
  • Page 19 CAUTION! Ø End of the line to the main tank must be open to the atmosphere and line pressure must be zero, otherwise no healthy modulating operation can be ensured since the pressure, which is to form in return, will also affect nozzle pressure. Fuel may drop from nozzle end during stops.
  • Page 20 BT 300 13.06.2017 Rev. 01...
  • Page 21: Operating Control And Displays

    Operating Control and Displays 1 Display 2 Back key 3 Cursor keys 4 Enter key Display: The display shows in pictograms: 1 - the menu structure 2 - operating status 3 - parameters 4 - error messages Back key: Jump to previous window. Cursor keys: You navigate in the menu using the cursor keys.
  • Page 22: Menu Functions

    Menu Functions The menu is divided intothree paths: INFO MANUAL SETTINGS INFO Select the INFO path for information about the following: the burner • errors that have occurred • the software version • display of check sums • the serial number •...
  • Page 23: Bt300 Connecting Diagram

    BT300 Connecting Diagram X30 = User Interface UI 300 X31 = LSB Option X32 = continuous output 1, e.g. air damper X33 = continuous output 2, e.g. gas damper X34 = continuous output 3 (optional) SIC = safety interlock chain 230V AC 47 - 63Hz external fuse protection required (max 10A slow-blow) 230V AC for power supply to external devices Maximum Cable Length:...
  • Page 24: Servomotor

    Servomotor Servomotors drive air dampers, gas butterfly valve and oil regulator. With the help of servomotors electronic air and fuel ratio control is carried out, controlled by burner control. Ø Static electricity can damage servomotor. Ø Do not open servomotor. Do not interfere with or modify unit or equipment connected to it. It may damage servomotor or change burner settings.
  • Page 25: Function Controls And Adjustments

    Function Controls and Adjustments The BT300 combines the benefits of an electronic fuel-air ratio control system with up to three motorised actuating devices and an optional modules like an analogue output for speed control of the combustion air fan with an electronic burner control unit. The leakage test, flame monitoring system, power control unit and (optional) CO/O2 controller for control and optimi-sation of an oil or gas-fired forced-draught burner are all integrated.
  • Page 26 Ø Oil adjustment regulator 1- Connecting rod 2- Scale coupler 3- Fuel connection points 4- Adjustment fixing bolt 5- Adjustment bolt 6- Housing cover (screw hood) Fuel regulator adjustment 1- Remove the housing cover number 6 2- Loosen the fixing bolt number 4 3- When you rotate the shaft number 5 (when looked from the shaft end) clockwise, the pressure value you observe from return manometer will increase, and burner consumption will also increase since nozzle pressure increases.
  • Page 27 13.06.2017 Rev. 01...
  • Page 28: Pilot Ignition System

    Pilot Ignition System Pilot gas burner inlet pressure Pmax= 200 mbar Emission Measurement In emission measurements, the following values are accepted as reference according to TS EN 267 standard. Ø CO < 110 mg/ kWh Ø %3 ≤ O ≤ %5 Ø...
  • Page 29: Heavy Oil Burner Fuel Ring Line

    Heavy Oil Burner Fuel Ring Line 13.06.2017 Rev. 01...
  • Page 30: Maintenance

    MAINTENANCE Weekly Maintenance Weekly maintenance is a routine cleaning and adjustment procedure which is performed to ensure smooth and continuous operation of the system. Burner components must be adjusted after each maintenance work in accordance with the instructions. Otherwise, the burner cannot be operated efficiently.
  • Page 31: Seasonal Maintenance

    Seasonal Maintenance Comprehensive maintenance work when the burner is re-started after long periods of shut-down or interruptions. After completion of maintenance and adjustment processes, make sure to perform a combustion analysis. Ø Check insulation resistance of electric motor. Ø Make surface cleaning of ignition electrodes and porcelains. Replace cracked or broken porcelains.
  • Page 32: Fault History

    FAULT HISTORY Reading fault situation from the control panel Active fault situation is shown on display. Enter-button is lit. Fault history can be read from the control panel. See more precise fault codes in the brochure on burner control. Resetting fault Example ●...
  • Page 33: Periodical Flue Gas Measurement Report

    PERIODICAL FLUE GAS MEASUREMENT REPORT Fuel Yield Flue Consumption (ppm) (ppm) (ppm) Temp. Date Signature (kg/h) (ºC) 13.06.2017 Rev. 01...
  • Page 34: After Sales Services

    Fax: +90 282 685 42 09 Also you can contact with us: Web site : www.ecostar.com.tr E - mail : servis@ecostar.com.tr Please observe the following recommendations. • Use the product in accordance with the principles of this manual. • For any service demands regarding the product, please contact our Service Center from the abovementioned phone numbers.
  • Page 35: Notes

    NOTES Please record and forward your measurements and observations to us www.ecostar.com.tr 13.06.2017 Rev. 01...