Outputs: Distributed High Impedance ("T" Models Only) - QSC ISA 300T User Manual

Isa series installed sound amplifiers
Hide thumbs Also See for ISA 300T:
Table of Contents

Advertisement

CONNECTIONS:
The ISA 300T, ISA 500T and ISA 800T amplifiers have high impedance (Hi-Z) outputs suitable for driving 25, 70, and 100 volt distributed
audio lines. These loads should be driven by the amplifier in stereo or parallel modes. For 140 volt or 200 volt output, the amplifier
must be configured for bridge mode. Bridge mode connections to the high impedance distributed outputs is discussed on the following
page. In the diagrams below, only one speaker load for each channel is shown for clarity. Distributed lines usually have several speaker
loads on each output line.
Stereo and Parallel Amplifier Mode Distributed Output Connections-
Use these terminals for 25, 70 or 100 volt distributed loads when the amplifier is in stereo or parallel mode.
25 volt lines:
Connect one of the 25 volt lines to the CH1 terminals
marked 25V.
Connect the other 25 volt line to the CH2 terminals
marked 25V.
The 25V connection is between the
markings.
Ensure proper polarity is maintained for all connections.
70 volt lines:
Connect one of the 70 volt lines to the CH1 terminals
marked 70V.
Connect the other 70 volt line to the CH2 terminals
marked 70V.
The 70V connection is between the
markings.
Ensure proper polarity is maintained for all connections.
100 volt lines:
Connect one of the 100 volt lines to the CH1 terminals
marked 100V.
Connect the other 100 volt line to the CH2 terminals
marked 100V.
The 100V connection is between the
markings.
Ensure proper polarity is maintained for all connections.
OUTPUT TERMINAL SAFETY WARNING!
Do not touch output terminals while amplifier power is on. Make all
connections with amplifier turned off. Risk of hazardous energy!
22
OUTPUTS-
DISTRIBUTED HIGH IMPEDANCE (HI-Z) , STEREO & PARALLEL
70
and
100
0
and
70
0
and
100
25 Volt Stereo or Parallel Connection
70 Volt Stereo or Parallel Connection
100 Volt Stereo or Parallel Connection
Class 2 wiring may be used. For
bridged mono and 100V distributed
outputs, class 1 wiring must be used.