A. This appliance must be lighted by match lighting
each time it is used. When lighting, follow these
instructions exactly.
B. BEFORE LIGHTING, smell all around the appliance
area for gas. Be sure to smell next to the floor be-
cause some gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
1. STOP! Read all the above safety information before proceeding.
BE SURE THAT THE CHIMNEY DAMPER IS
WARNING
FULLY OPEN.
2. Turn shutoff valve clockwise
17).
3. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP!
Follow the above safety instructions titled "WHAT TO DO IF YOU SMELL
GAS. " If you do not smell gas, go to the next step.
4. Place a burning match on the surface of the burner embers. Do not
hold the match in your hand.
5. Slowly turn the shutoff valve counterclockwise
position. The gas will ignite in five (5) seconds. If there is no ignition
within ten (10) seconds of placing the match, turn the shutoff valve
clockwise
1. Turn the shutoff valve clockwise
©2017 Pinnacle Climate Technologies
FOR YOUR SAFETY READ BEFORE LIGHTING
If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
LIGHTING INSTRUCTIONS
to the OFF position (see Figure
to the OFF position and repeat steps 1–4.
TO TURN OFF GAS TO THE APPLIANCE

Operation

• If you cannot reach your gas supplier, call the fire
department.
C. Push in or turn the gas control knob using only
your hand. Never use tools. If the knob will not
push in or turn by hand, do not try to repair
it; call a qualified service technician. Force or
attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been
underwater. Immediately call a qualified service
technician to inspect the appliance and to
replace any part of the control system and any
gas control that has been underwater.
to the ON
to the OFF position (see Figure 17).
13
Fig. 17—Shutoff Valve
Vented Gas Log Appliance User's Manual
Open/
On
Closed/
Off