Daily Operations

To do this . . .
Turn the power on.
Turn the power off.
Scan the temperatures
of each zone.
Monitor the temperature
of a zone.
Place the system in
standby.
Take the system out of
standby.
Turn the heaters on.
Turn the heaters off.
Turn the 7-day clock on.
Turn the 7-day clock off.
Turn the pump on.
Turn the pump off.
Determine whether a
fault was corrected.
Turn the Pattern
Control on.
Turn the Pattern
Control off.
Original copyright date 1/98. Nordson is a registered trademark of Nordson Corporation.
O1EN–OPC–[3V–237532]–12
Press this key . . .
This happens . . .
The POWER switch turns on.
The POWER switch turns off.
The MONITOR/SCAN light
turns on and stays on.
The MONITOR/SCAN light
stays on.
The STANDBY light turns on.
The STANDBY light turns off.
The HEATERS light turns on.
The HEATERS light turns off.
The CLOCK light turns on.
The CLOCK light turns off.
The PUMP light turns on.
The PUMP light turns off.
All LED lights turn on while
the system begins a
five-second test. At the end
of the test, the FAULT light
turns off.
All LED lights turn on while
the system begins a
five-second test. At the end
of the test, the FAULT light
stays on.
The PATTERN CONTROL
light turns on.
The PATTERN CONTROL
light turns off.
6
It means . . .
Power to the unit is on.
Power to the unit is off.
The system scans each
heated zone and displays
each zone's temperature.
The system displays the
temperature of only the
zone currently selected.
Heating zones hold at
your preset standby
temperatures.
Heating zones return to
your operating setpoint
temperatures.
The tank, hoses, and
guns are heated.
No heat is applied to
system components.
The system performs
functions controlled by
the clock.
The system does not
perform functions
controlled by the clock.
The pump draws melted
material through the
system.
The pump stops drawing
melted material through
the system.
The fault was corrected.
The fault was not
corrected.
The system applies your
preset patterns.
The pattern control is off.