Instruction CF-RF Room Thermostat with Infrared Floor Sensor
Setting of room temperature
. Make sure actual room temperature is shown
in the display
2. Press the up/down selector
desired room temperature value. SET is shown
in the display
3. When releasing the up/down selector
display returns to actual temperature
Note: The thermostat regulates the floor heating system
according to room temperature set point, within the
maximum and minimum limitations defined for the floor
surface temperature
Room temperature limitation
. Make sure actual room temperature is shown
in the display
2. Press the push button
shown in the display
3. Press the up/down selector
maximum room temperature limitation
4. Press the push button
shown in the display
5. Press the up/down selector
minimum room temperature limitation
6. Press the push button
actual floor surface temperature is shown in
the display
VI.UH.R2.1C
until SET MAX is
shortly, SET MIN is
shortly and the
Produced by Danfoss Floor Heating Hydronics 03.2007
to set the
the
to set the
to set the
GB