Sakata SOB-50VA Service Manual page 24

Light commercial air conditioner r410a on/off
Table of Contents

Advertisement

Light Commercial R410A on-off
(8) Swing angle of louver
1)
Add one more swing motor, one motor driving two louvers. Controlling the interspace
of each part, minimizing the angle loss.
2)
The swing angle of the first louver are 40~42 degrees and the second louver are
37~38 degrees. New evaporator and inner configuration designed can acquire high
heat-exchanger effect.
(9) More strengthening rib design around the panel, preventing the distortion for the panel.
(10) New outlet frame design to make the phenomena of coagulation great improvement:
prevent the condensing water from damaging the air guide strip.
(11) Adding rib on the panel of fan outlet, which can avoid the air outlet direct flow to people.
(12) Adding digital tube displaying on the display board. LED can display the Error Code to
make the malfunction checking easier.
(13) Reserve spaces for air side-outlet, it is available to connect duct pipe hence air supplying
from the four sides to nearby small room..
Indoor Units. Four-way Cassette Type
S13-01.01.13en
23