Main menu a. Raise/lower temperature Installation Guide…………....……… 3 b. Use c. Schedule c.1 Programming c.2 Holidays First connection 1. Welcome to momit Smart d.1 General setup Thermostat d.1.1 Hysteresis 2. Language d.1.2 Calibration 3. Smart Registration d.1.3 Screen Lock 4. Date/Time d.2 Advanced...
(also known as COM) and W (also known as NO) wires, these are the control wires. You will need these wires for momit Smart Thermostat to work. If you don’t have these wires, you will have to install them. Once you have done this, proceed...
Page 4
Open momit Smart Thermostat. To do so, insert the tip of a fl athead screwdriver into the openings found at the bottom. Gently press the openings while prying. Make a hinge movement to fi nish opening the thermostat case without forcing the connection pins.
Page 5
Position the back plate on the wall. Make sure that none of the labels fall out when attaching the wall plate. Insert the screws and tighten them up. Now you can begin to connect the wires. Below you can fi nd the wiring diagram for heat and cooling systems.
Page 6
This means it has been wedged in properly. Now you can turn the power supply back on and continue with the momit Smart Thermostat setup.
First time connection The first time you connect your momit Smart Thermostat, a series of screens will appear, which will take you through the initial device setup. Welcome Welcome to momit Smart Thermostat, the smart WiFi thermostat.
Smart Registration option informing you if you are enabled for Smart Registration. If yes, proceed to step 4. Later you will be provided with a registration code you must enter in the momit Smart Thermostat App. continue>>...
Page 9
If not, the following screen will appear. SET-UP User Conditions By accepting, you are agreeing to comply with the user conditions when using the momit Smart Thermostat. Before continuing, you may consult the user conditions at www.momit.com I do not accept accept...
Page 10
Create user account I already have an account delete accept Enter the email address you will use to access your momit Smart Thermostat. SET-UP Create a personal password to be able to control your thermostat. It must E-mail have at least 6 characters.
Date/Time Select the current date and time to SETTINGS start programming the thermostat. momit Smart Thermostat will automatically update the time when Date/Time appropriate. DD/MM/YY MM/DD DD/MM HHMM 1 2 3 4 5 6 7 8 9 0 delete accept...
Network Detection The networks to which the device may SETTINGS be connected appears on the screen. The network name may also be entered Networks - SSID found manually. Network 1 Network 2 If you select DHCP IP, a dynamic IP will Network 3 be assigned to the thermostat.
User Registration The code you need for Smart SETTINGS Registration will show up. Enter it and follow the instructions on User Register the App. If you do not have Smart Registration, proceed with step 8. Download the APP and register your device with next code FF0033DD66EE accept...
Display Design Using the side buttons, you may browse through the designs and select the one you want by clicking in the centre of the screen. 6 display modes: Standard Simple Elegant Retro Maya Minimalist Elegant...
Page 15
Temperature reading Maya The tens and units are shown in the bottom left. Tens The tens are represented by hollow circles, while the units are represented Units by solid circles. Minimalist In this case, 3 bars appear: the middle one represents the units (the highest), the left one represents the tens 0 1 2 3 4...
Main menu Once the initial setup has been completed upon fi rst connecting your momit Smart Thermostat, every subsequent time that the device is turned on, you will be taken directly to the main menu. If you do not have Smart Registration, your thermostat must have been updated before you can view the current functions.
Raise/Lower Temperature With a single tap on the screen, the “+” and “–” symbols will appear. ° 21.4 Use these symbols to select the desired temperature, and once selected, click OK. SETTINGS Allows you to select the heating, cooling or Off function. What you do you want to enable? Heating delete...
Schedule Programming This section shows the Schedule. 0.00 1.00 2.00 3.00 4.00 5.00 The colour red indicates heating, Monday and blue indicates cooling. Hours appear at the top and days on the Tuesday 22ºC left. Wednesday There are two options in Schedule: Thursday 19ºC Friday...
Holidays CALENDAR When a holiday period is confi gured, momit Smart Thermostat will turn off Holidays the heating or cooling systems until the return date. I am Leaving When in Holidays mode, the following icon will appear on the screen:...
General Setup GENERAL SETTINGS Allows you to access: Language - Language - Date/Time - F/C Date/Time - Calibration - Screen Lock Calibration Lock...
Page 21
This term refers to the difference between the current (ambient) temperature and the set target temperature (momit temperature), so that the heating and cooling systems will switch on and off. It is the margin assigned to the momit temperature to stop or start the HVAC system operating.
Advanced ADVANCED Allows you to turn the modes on and off: momit Modes d.2.1 Smart d.2.2 Presence Smart d.2.3 Ambient d.2.4 Standby Presence d.2.1 Smart Ambient Smart mode automatically learns Standby your routines of use, configuring itself based on this data. This mode will operate after 3 manual...
d.2.4 Standby After 1 minute of no activity on the thermostat, the Standby mode will turn off the screen and enter into low energy consumption mode. º º 21,4 21,4 Manual Schedule When this status is in control, a hand When a schedule programme is active, this will appear on the screen: icon will appear on the screen: By tapping on it, the thermostat will...
Technical TECHNICAL SETTINGS Allows you to access: d.3.1 Technical information Technical Information d.3.2 Network d.3.3 Reset Network Reset d.5.1 Technical information d.5.2 Network TECHNICAL TECHNICAL Technical Information Detect Networks Firmware Version 2.0 Manual entry of WiFi entering S/N: 190005649522884 Test connection MAC: ACCF233ECOC4 delete accept...
Minimum requirements momit Smart Thermostat allows you to control heating and cooling systems using potential-free relays for a simple two-wire installation. The control circuit systems that will be managed must not exceed the maximum relay operating values of the thermostat, described below: - Relays able to operate at 5A with resistive load and 2A with inductive load as a maximum.