All alarm threshold parameters can be inquired including high alarm
threshold and low threshold.
To ensure the security, the threshold only can be changed by webmaster.
LCD keyboard can not operate on it locally. To avoid wrong settings to damage
laser, even in webmaster, key alarm thresholds are not allowed to be changed
(like laser drive level).

8. Network Management

There are two kinds of network management: Industrial bus mode or
national standard class 2 transponder mode. Either-or choice, should be made
before leaving factory, user can not change it again.
8.1 Industrial Bus Mode
Without NE2, 0T10U series indoor 1310 optical transmitter can connect to
PC through RS232 port or RS485 port (this function will be disabled with NE2
configured). One PC can connect to multiple same model receivers, receivers
will be recognized by their MAC address as each device has different MAC
address, which can be checked on LCD.
8.2 National Standard Class 2 Transponder Mode
HF200-3613 series indoor 1310 optical transmitter can configure with NE2
optionally, with webmaster that meets national standard, remote control for
optical transmitters can be achieved.
To connect webmaster, optical transmitter must configure correct IP address
based on user network situation.
NE2 factory default IP address is: 192.168.0.1. There are two ways to
change IP.\:
Telnet Method
If user know the IP of the device, set the IP of PC in the same net segment
User's manual