Download Print this page

Troubleshooting - Pyle PINV5 Owner's Manual

600/800/1000watt

Advertisement

TROUBLE SHOOTING
SYMPTOM A: NO AC POWER OUTPUT, THE RED LED LIGHTS.
POSSIBLE CAUSES
The connected AC products are rated at more than 600 Watts
(PINV4) , 800 Watts (PINV5) or 1000 Watts (PINV6), the
overload shutdown occurred.
The connected AC products are rated at less than 600 Watts
(PINV4) , 800 Watts (PINV5) or 1000 Watts (PINV6), the high
starting surge causes the overload shutdown.
The battery is discharged (alarm sounds)
The inverter overheated
SYMPTOM B: NO AC POWER OUTPUT, NO LED LIGHTS ARE ON.
POSSIBLE CAUSES
The fuse of inverter is blown
The inverter has been connected with reverse DC input
polarity.
SUGGESTION
Use the product with a total power rating
less than 600 Watts (PINV4) , 800 Watts
(PINV5) and 1000 Watts (PINV6) .
Use the product not exceeds the inverter's
surge capacity, 1200 Watts (PINV4) , 1600
Watts (PINV5) and 2000 Watts (PINV6) .
Recharge battery.
Turn off the inverter and allow to cool for
15 minutes. Clear blocked fan (PINV4 /
PINV5 / PINV6) or remove the objects
covering the ventilation.
SUGGESTION
Check to make sure the inverter is
connected to a power source with correct
voltage and polarity.
Replace fuse.
The inverter needs repairment
if the probable damage has occurred.
6

Advertisement

loading

This manual is also suitable for:

Pinv4Pinv6