Panasonic PT-DZ12000U Service Manual page 15

Dlp based projector
Hide thumbs Also See for PT-DZ12000U:
Table of Contents

Advertisement

Self-
Contents
diagnosis
display
U15
Optical output restriction for the
projector protection
U21
Temperature error (IN)
U22
Temperature error (OPT)
U23
Temperature error (OUT)
U24
Low temperature error (OPT)
U41
Lamp 1 operating time warning
U42
Lamp 2 operating time warning
U43
Lamp 3 operating time warning
U44
Lamp 4 operating time warning
U61
Lamp 1: 2 000 hour operating time
exceeded
U62
Lamp 2: 2 000 hour operating time
exceeded
U63
Lamp 3: 2 000 hour operating time
exceeded
U64
Lamp 4: 2 000 hour operating time
exceeded
U51
Lamp 1 going out
U52
Lamp 2 going out
U53
Lamp 3 going out
U54
Lamp 4 going out
U51
Lamp 1 lighting failure
U52
Lamp 2 lighting failure
U53
Lamp 3 lighting failure
U54
Lamp 4 lighting failure
U70
Air filter unit not installed
U71
Lamp 1 not installed
U72
Lamp 2 not installed
U73
Lamp 3 not installed
U74
Lamp 4 not installed
U75
Special filter setting
U81
AC power supply voltage drop
warning (less than 99 V)
U91
Lamp unit cover is not closed
H11
Thermosensor disconnected (IN)
H12
Thermosensor disconnected (OPT)
H13
Thermosensor
(OUT)
H18
Airflow sensor disconnected
U04
Air filter is blocked
H01
Internal clock battery replacement
Shutdown
40 °C (35 °C when ALTITUDE MODE is ON) or
higher in ambient temperature at QUAD mode
Intake air temperature is the specific value or
higher.
Optical module temperature is the specific
value or higher.
Lamp surroundings temperature is the specific
value or higher.
*1
Optical module temperature is less than 5°C.
Lamp cumulative usage time is 1 800 hour or
longer.
*2
*2
Lamp cumulative usage time is 2 000 hour or
longer.
*2
*2
*2
Lamp goes out after turning on.
*2
*2
*2
*2
Lamp ignition failure
*2
*2
*2
Air filter unit is not installed.
Lamp is not installed (The lamp memory cannot
be read.)
SPECIAL has been selected on AIR FILTER in
EXTRA OPTION menu.
AC power supply voltage drops.
Lamp unit cover is not closed for 1 second or
longer.
Intake air thermosensor is disconnected.
Optical module thermosensor is disconnected.
disconnected
Lamp
disconnected.
Airflow sensor is disconnected.
The air filter accumulates dust.
The date is before December 31, 2005 or after
January 1, 2036.
PT-DZ12000U / PT-DZ12000E / PT-D12000U / PT-D12000E / PT-DW100U / PT-DW100E
Display condition
surroundings
thermosensor
15
Remarks
After turning on the power, the
shutdown processing is not
done for 2.5 minutes.
LAMP monitor lights in red.
After turning on the lamp, it will
turn off in 10 minutes. LAMP
monitor lights in red.
LAMP monitor blinks 3 times in
red.
LAMP monitor blinks 3 times in
red.
Confirms the installation when
turning on the power.
LAMP monitor blinks 3 times in
red.
This display is not an error.
If the cover is not closed when
turning on the power, it does
not turn on.
is
If this error occurs, the date is
reset on 00:00:00, January 1,
2006.